background image

2. THE BEST AREAS TO INSTALL THE HEAT 

ALARM:
• Kitchen area

• Garage or workshop
Additional alarms increase the security.

3. AREAS WHERE NOT TO INSTALL HEAT-

ALARMS:

• In rooms where the temperature goes outside 

-10ºC to +50ºC.

• Bedrooms

• Lounge

• Dining room

• Hallway

• Family room
NOTE:  In  areas  where  smoldering  fires  occur 

over  flaming  fires,  photoelectric  smoke  alarms 

are still the best to be installed. 
4. PLACEMENT:
The heat alarm is design to be installed on a ceiling 

or wall. Do not install to close to the oven/hob/

stove (see drawing).
For wall installation:

For celling installation:

5. INSTALLING THE HEAT ALARM:
Detach the alarm from the mounting base by 

twisting counter clockwise.

MARK UP 

SCREW HOLES 

WITH A PEN

All alarms that need to be connected in the 

house should be put into ‘Learn Mode’ by sliding 

the switch on the back of the alarm to the ‘Learn 

Mode’ position. 

  

The red LED will light up to indicate that ‘Learn 

Mode’ has been selected. 

Please note that when the alarms are placed 

in ‘Learn Mode’ they can’t be inserted into the 

mounting base. 
Press and hold the test button at one alarm only, 

until it beeps and the LED flashes. This alarm will 

become the master and will start sending out a 

specific house code to the other alarms. 

As  the  other  alarms  receive  the  specific  house 

code, they will also flash the LED light.

When  the red LED light flashes on all alarms, 

they are connected and MUST BE SWITCHED 

OUT OF ‘LEARN MODE’ and installed. 
Label the original “Learn” alarm in order to easily 

add new CAVIUS Wireless Family alarms to the 

system.

Thermal heat alarm device

Commercial reference: 3106-008

Developed by CAVIUS
This Thermal Heat Alarm is designed for areas not 

suitable for smoke alarms due to high risk of false 

alarms such as; kitchens, garages or workshops.

PLEASE READ THE INSTALLATION GUIDE 

CAREFULLY BEFORE INSTALLATION AND 

RETAIN FOR FUTURE USE.

SAFETY INSTRUCTIONS:

The device comes with a 3V lithium battery. Bat-

teries are to be handled with care and battery pow-

ered devices should be kept out of reach of chil-

dren. Do not try to recharge or burn the batteries. 
TECHNICAL INFORMATION:

Cavius heat alarm detects: 

1) rapidly increased temperature level

2) absolute heat level of 58 degrees C. 
The maximum number of alarms that can be inter-

linked within a house group are 32. 
Please note: These must be alarms from the CAVIUS
 

The distance between interlinked alarms depends 

on the house layout and they should always be 

tested after installation. It is not advised to get 

more than 10m distance between two alarms.
Diameter: 78mm. Height: 42mm.

The alarm is powered by a non-replaceable 3v 

CR123A lithium battery.
Complies  to  standards:  EN54-5  class  A1/R, 

EN300-220, Kitemark BS 5446 part2.

1. HOW TO SET UP AND CONNECT ALARMS:  
Please note: The product label must not be 

removed as it contains important information 

regarding the product. 

UK

MOUNTING

BASE

TEST BUTTON

RED LED

THERMISTOR

Peak ceiling

Minimum 15cm 

from peak

Minimum 15cm and 

maximum 30cm from 

ceiling

Wall

Ceiling

Minimum 30cm

and maximum 50cm 

from stove

Ceiling

Minimum 30cm 

from wall

Wall

Ceiling

LEARN MODE

NORMAL MODE

Heat

Siting of Heat alarms

INSTALLATION

G U I D E

Reviews: