Home Standby - 7kW - 12kW - 15kW

ˆ

INNOVATIVE DESIGN & PROTOTYPE TESTING are key components
of CARRIER’S success in “IMPROVING POWER BY DESIGN.” But it 
doesn’t stop there. Total commitment to component testing, reliability 
testing, environmental testing, destruction and life testing,  plus testing
to applicable CSA, NEMA, EGSA, and other standards, allows you to 
choose CARRIER with the confidence that these systems will provide
superior performance.

ˆ

TEST CRITERIA:

>

PROTOTYPE TESTED

>

SYSTEM TORSIONAL TESTED

>

NEMA MG1-22 EVALUATION

>

MOTOR STARTING ABILITY

ˆ

SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE
REGULATION. 
This state-of-the-art power maximizing regulation
system is standard on all CARRIER models. It provides optimized
FAST RESPONSE to changing load conditions and MAXIMUM
MOTOR STARTING CAPABILITY by electronically torque-matching the
surge loads to the engine.

ˆ

SINGLE SOURCE SERVICE RESPONSE from CARRIER’s dealer
network provides parts and service know-how for the entire unit, from
the engine to the smallest electronic component. You are never on
your own when you own a CARRIER system.

ˆ

CARRIER TRANSFER SWITCHES. Long life and reliability are 
synonymous with CARRIER systems. One reason for this confidence
is that the CARRIER product line includes its own transfer systems
and controls for total system compatibility.

FEATURES

Air-Cooled Gas Engine Generator Sets

Continuous Standby Power Rating 

Model ASPAS1CCA007 - 7kW 60Hz

Model ASPAS1CCA012 - 12kW 60Hz
Model ASPAS1CCA015 - 15kW 60Hz

INCLUDES:
• Automatic Transfer Switch 

with Built-In Emergency Load Center 

• Pre-wired External Connection Box 

• Flexible Fuel Line 

• Composite Mounting Pad  

• Pre-wired conduits

• Natural Gas or LP Gas Operation

• GFCI duplex outlet & 12Vdc outlet

• UL Listed to Canadian safety standards

• 2 Year Limited Parts and Labor Warranty

TRANSFER SWITCH & 

Model ASPAS1CCA007

Model ASPAS1CCA012

Model ASPAS1CCA015

EMERGENCY LOAD CENTER

(7kW)

(12kW)

(15kW)

No. of Poles 

2

2

2

Current Rating (amps) ......................................................100 ..........................................100 ......................................... 100
Voltage Rating (VAC) ....................................................... 250 ......................................... 250 ......................................... 250
Utility Voltage Monitor (fixed)
-Pick-up ........................................................................... 70% ........................................ 70% ....................................... 70%
-Dropout ......................................................................... 60% ....................................... 60% ....................................... 60%
Return to Utility ....................................................... approx. 13 sec  .......................approx. 13 sec. ....................... approx. 13 sec.
Exerciser weekly for 12 minutes .................................. Standard .................................Standard .................................Standard
UL Listed ...................................................................... Standard .................................Standard .................................Standard
Dimensions (H” x W” x D”) .......................................26.5 x 12.5 x 7 ...................... 26.5 x 12.5 x 7 ....................... 26.5 x 12.5 x 7
Total of Pre-wired Circuits .................................................. 8 ............................................ 10 ...........................................12

No. 15A 120V .......................................................... 5 ............................................ 3  ........................................... 5
No. 20A 120V .......................................................... 1 ............................................ 3  ........................................... 3
No. 15A 240V .......................................................... - ............................................ -  ........................................... -
No. 20A 240V .......................................................... - ............................................ 1  ........................................... 1
No. 30A 240V .......................................................... 1 ............................................ 1  ........................................... 1

Circuit Breaker Protected 

Available RMS Symmetrical
Fault Current @ 250 Volts ...................................10,000 .....................................10,000 ......................................10,000

CARRIER, INC. •  7310 WEST MORRIS STREET  •  INDIANAPOLIS, IN 46231 • www.carrier.com

Printed in USA 10.05

CATALOG NO. ASPAS07-2SS

All specifications are subject to change without notice.

Mechanical Dimensions (in inches)
Current No. of 

Height

Width

Depth

Rating

Poles

H1

H2

W1

W2

100 UL Listed

2

26.5

29.25

8.14

12.5

7

W1

W2

H1

H2

Terminal Wire Ranges
ATS Rated Amps

Switch Terminal

Neutral Lug/Stud

Ground Lug

100A 2-Pole UL

1 x 1/0-12

1 x 3/8-16 Stud

1 x 2/0-14

Transfer Switch Features

• Electrically 

operated,

mechanically-held contacts for
fast, positive connections.

•  Rated for all classes of load,

100% equipment rated, both
inductive and resistive.

•  2 pole, 250 VAC contactors.

•  160 millisecond transfer time.

•  Dual coil design.

•  Main contacts are silver plated or

silver alloy to resist welding and
sticking.

•  NEMA 1 enclosure is standard on

the 100 amp switch.

Home Standby - 7kW - 12kW - 15kW