16
Table 3 — 23XRV Heat Exchanger Sizes A,B Dimensions (Nozzle-in-Head Waterbox)
a,b,c,d,e,f
NOTE(S):
a. Service access should be provided per American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) 15, latest edition, National Fire Protection
Association (NFPA) 70, and local safety code.
b. Allow at least 3 ft (915 mm) overhead clearance for service rigging for compressor.
c. Certified drawings available upon request.
d. Marine waterboxes may add 6 in. (152 mm) to the width of the machine. See certified drawings for details.
e. ‘A’ length dimensions shown are for standard 150 psig (1034 kPa) design and Victaulic connections. The 300 psig (2068 kPa) design and/or flanges will add length. See
certified drawings.
f.
Dished head waterbox covers are available only for 2-pass design.
HEAT EXCHANGER
SIZE
A (LENGTH)
g
g. 1 or 3 pass length applies if either (or both) cooler or condenser is a 1 or 3 pass design. The 2-pass length assumes both cooler and condenser nozzles on same end of chiller.
B (WIDTH)
C (HEIGHT)
1-Pass
2-Pass
3-Pass
ft-in.
mm
ft-in.
mm
ft-in.
mm
A
14- 6-3/4
4439
14- 1-1/4
4301
14- 6-3/4
4439
See unit certified drawings
B
16- 3-1/4
4959
15- 9-3/4
4822
16- 3-1/4
4959
Table 4 — 23XRV Heat Exchanger Sizes A,B Dimensions (Marine Waterbox)
a,b,c,d,e,f
NOTE(S):
a. Service access should be provided per ASHRAE 15, latest edition, NFPA 70, and local safety code.
b. Allow at least 3 ft (915 mm) overhead clearance for service rigging for compressor.
c. Certified drawings available upon request.
d. Marine waterboxes may add 6 in. (152 mm) to the width of the machine. See certified drawings for details.
e. ‘A’ length dimensions shown are for standard 150 psig (1034 kPa) design and Victaulic connections. The 300 psig (2068 kPa) design and/or flanges will add length. See
certified drawings.
f.
Dished head waterbox covers are available only for 2-pass design.
HEAT EXCHANGER
SIZE
A (LENGTH)
g
g. 1 or 3 pass length applies if either (or both) cooler or condenser is a 1 or 3 pass design. The 2-pass length assumes both cooler and condenser nozzles on same end of chiller.
B (WIDTH)
C (HEIGHT)
1-Pass
2-Pass
3-Pass
ft-in.
mm
ft-in.
mm
ft-in.
mm
A
15- 9
4801
14- 6-1/2
4435
15- 5
4699
See unit certified drawings
B
17- 5-1/2
5322
16- 3
4955
17- 1-1/2
5220
Table 5 — 23XRV Dimensions Heat Exchanger Sizes 30-57 (Nozzle-In-Head Waterbox)
a,b,c,d,e,f
NOTE(S):
a. Service access should be provided per ASHRAE 15, latest edition, NFPA 70, and local safety code.
b. Allow at least 3 ft (915 mm) overhead clearance for service rigging for frame R compressor.
c. Certified drawings available upon request.
d. Marine waterboxes may add 6 in. (152 mm) to the width of the machine. See certified drawings for details.
e. ‘A’ length dimensions shown are for standard 150 psig (1034 kPa) design and Victaulic connections. The 300 psig (2068 kPa) design and/or flanges will add length. See
certified drawings.
f.
Dished head waterbox covers not available for 3 pass design.
HEAT EXCHANGER
SIZE
A (LENGTH, WITH NOZZLE-IN-HEAD WATERBOX)
B (WIDTH)
C (HEIGHT)
1-Pass
2-Pass
g
g. Assumes both cooler and condenser nozzles on same end of chiller.
3-Pass
ft-in.
mm
ft-in.
mm
ft-in.
mm
30 to 32
14- 3-1/4
4350
13- 8-1/4
4172
14- 3-1/4
4350
See unit
certified
drawings
35 to 37
15-11-3/4
4870
15- 4-3/4
4693
15-11-3/4
4870
40 to 42, 4D
14- 9
4496
14- 3-1/8
4347
14- 6
4420
45 to 47, 4E
16- 5-1/2
5017
15-11-5/8
4867
16- 2-1/2
4940
50 to 52
14-10
4521
14- 4-1/2
4382
14- 6-1/2
4432
55 to 57
16- 6-1/2
5042
16- 1
4902
16- 3
4953
Table 6 — 23XRV Heat Exchanger Sizes 30-57 Dimensions (Marine Waterbox)
a,b,c,d,e
NOTE(S):
a. Service access should be provided per ASHRAE 15, latest edition, NFPA 70, and local safety code.
b. Allow at least 3 ft (915 mm) overhead clearance for service rigging for frame R compressor.
c. Certified drawings available upon request.
d. Marine waterboxes may add 6 in. (152 mm) to the width of the machine. See certified drawings for details.
e. ‘A’ length dimensions shown are for standard 150 psig (1034 kPa) design and Victaulic connections. The 300 psig (2068 kPa) design and/or flanges will add length. See
certified drawings.
HEAT EXCHANGER
SIZE
A (LENGTH, MARINE WATERBOX)
B (WIDTH)
C (HEIGHT)
2-Pass
f
f.
Assumes both cooler and condenser nozzles on same end of chiller.
1 or 3-Pass
g
g. 1 or 3 pass length applies if cooler is a 1 or 3 pass design.
ft-in.
mm
ft-in.
mm
30 to 32
14- 9
4496
16- 4-3/4
4997
See unit
certified
drawings
35 to 37
16- 5-1/2
5017
18- 1-1/4
5518
40 to 42, 4D
15- 2-3/4
4642
16- 3-1/4
5086
45 to 47, 4E
16-11-3/4
5163
18- 4-3/4
5607
50 to 52
15- 3-1/2
4661
16- 8-1/2
5093
55 to 57
17- 0
5182
18- 5
5613
Summary of Contents for AquaEdge 23XRV
Page 53: ...53 Fig 58 23XRV Controls Schematic ...
Page 54: ...54 Fig 58 23XRV Controls Schematic cont FROM 2000767952 SHEET 3 ...
Page 55: ...55 Fig 58 23XRV Controls Schematic cont ...
Page 56: ...56 Fig 59 23XRV Controls Schematic Rockwell Standard Tier VFD Shown ...
Page 57: ...57 Fig 60 23XRV LF2 VFD Wiring Diagram ...
Page 65: ...65 Fig 70 23XRV Insulation Area Units with P Compressor ...