179
APPENDIX A — ICVC PARAMETER INDEX
PARAMETER
MENU
SOFTKEY
TABLE
SCREEN NAME
CONFIGURABLE
1CR Start Complete
STATUS
ISM_STAT
1CR Stop Complete
STATUS
ISM_STAT
1M Start/Run Fault
STATUS
ISM_STAT
1M/2M Stop Fault
STATUS
ISM_STAT
1st Current Alarm State
SERVICE
CONTROL ALGORITHM STATUS
CUR_ALM
20mA Demand Limit Opt
SERVICE
EQUIPMENT SERVICE
RAMP_DEM
X
2M Start/Run Fault
STATUS
ISM_STAT
2nd Current Alarm State
SERVICE
CONTROL ALGORITHM STATUS
CUR_ALM
3rd Current Alarm State
SERVICE
CONTROL ALGORITHM STATUS
CUR_ALM
4th Current Alarm State
SERVICE
CONTROL ALGORITHM STATUS
CUR_ALM
5th Current Alarm State
SERVICE
CONTROL ALGORITHM STATUS
CUR_ALM
Active Delta Tsat
STATUS
COMPRESS
Active Delta Tsat
STATUS
HEAT_EX
Active Delta Tsat
SERVICE
CONTROL ALGORITHM STATUS
SURGEPREV
Active Demand Limit
STATUS
MAINSTAT
Active Region
SERVICE
CONTROL ALGORITHM STATUS
SURGEPREV
Actual Guide Vane Pos
STATUS
STARTUP
Actual Guide Vane Pos
STATUS
COMPRESS
Actual Guide Vane Pos
STATUS
HEAT_EX
Actual Guide Vane Pos
SERVICE
CONTROL ALGORITHM STATUS
CAPACITY
Actual Guide Vane Pos
SERVICE
CONTROL ALGORITHM STATUS
SURGEPREV
Actual Line Current
STATUS
POWER
Actual Line Voltage
STATUS
POWER
Actual Superheat
SERVICE
CONTROL ALGORITHM STATUS
OVERRIDE
Actual VFD Speed
STATUS
COMPRESS
Actual VFD Speed
SERVICE
CONTROL ALGORITHM STATUS
CAPACITY
Address
SERVICE
ICVC CONFIGURATION
Alarm Relay
STATUS
MAINSTAT
Alarm Routing
SERVICE
EQUIPMENT CONFIGURATION
NET_OPT
x
Amps or KW Ramp %/Min.
SERVICE
EQUIPMENT SERVICE
RAMP_DEM
X
Amps/KW Ramp
SERVICE
CONTROL ALGORITHM STATUS
CAPACITY
Auto Chilled Water Reset
STATUS
MAINSTAT
Auto Demand Limit Input
STATUS
MAINSTAT
Auto Restart Option
SERVICE
EQUIPMENT SERVICE
OPTIONS
X
Average Line Current
STATUS
MAINSTAT
Average Line Current
STATUS
POWER
Average Line Voltage
STATUS
POWER
Base Demand Limit
SETPOINT
SETPOINT
X
Baud Rate
SERVICE
ICVC CONFIGURATION
Broadcast Option
SERVICE
EQUIPMENT CONFIGURATION
NET_OPT
x
Bus Number
SERVICE
ICVC CONFIGURATION
Calc Evap Sat Temp
STATUS
HEAT_EX
Calc Evap Sat Temp
SERVICE
CONTROL ALGORITHM STATUS
OVERRIDE
CCN Mode ?
STATUS
ICVCPSWD
Chill Water Pulldown/Min
STATUS
HEAT_EX
Chilled Medium
SERVICE
EQUIPMENT SERVICE
SETUP1
X
Chilled Water Deadband
SERVICE
EQUIPMENT SERVICE
SETUP1
X
Chilled Water Delta P
STATUS
HEAT_EX
Chilled Water Delta T
STATUS
HEAT_EX
Chilled Water Delta T
SERVICE
CONTROL ALGORITHM STATUS
SURGEPREV
Chilled Water Flow
STATUS
STARTUP
Chilled Water Pump
STATUS
STARTUP
Chilled Water Temp
STATUS
MAINSTAT
Chilled Water Temp
SERVICE
CONTROL ALGORITHM STATUS
WSMCHLRE
Chiller Start/Stop
STATUS
MAINSTAT
CHW Delta T->Full Reset
SERVICE
EQUIPMENT SERVICE
TEMP_CTL
X
CHW Delta T->No Reset
SERVICE
EQUIPMENT SERVICE
TEMP_CTL
X
CHW Setpoint Reset Value
SERVICE
CONTROL ALGORITHM STATUS
WSMCHLRE
Commanded State
SERVICE
CONTROL ALGORITHM STATUS
WSMCHLRE
Common Sensor Option
SERVICE
EQUIPMENT SERVICE
LEADLAG
X
Comp Discharge Alert
SERVICE
CONTROL ALGORITHM STATUS
OVERRIDE
Comp Discharge Alert
SERVICE
EQUIPMENT SERVICE
SETUP1
X
Summary of Contents for AquaEdge 19XR series
Page 69: ...69 Fig 33 19XR Leak Test Procedures a19 1625 ...
Page 154: ...154 Fig 64 Benshaw Inc Wye Delta Unit Mounted Starter Wiring Schematic Low Voltage a19 1873 ...
Page 161: ...161 Fig 69 Typical Low Voltage Variable Frequency Drive VFD Wiring Schematic 575 v ...
Page 162: ...162 Fig 69 Typical Low Voltage Variable Frequency Drive VFD Wiring Schematic 575 v cont ...
Page 186: ...186 APPENDIX B LEAD LAG WIRING 19XR Lead Lag Schematic Series Cooler Flow a19 1655 ...
Page 187: ...187 APPENDIX B LEAD LAG WIRING cont 19XR Lead Lag Schematic Parallel Cooler Flow a19 1717 ...