background image

Please read the operating instructions and safety precautions carefully and thoroughly
before installing and operating your room air conditioner.

OWNER S MANUAL

Split Type Room Air Conditioner

Summary of Contents for AI10H-2

Page 1: ...Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner OWNER S MANUAL Split Type Room Air Conditioner ...

Page 2: ...ems in the chart of troubleshooting tips If you review the chart of Troubleshooting Tips first you may not need to call for service Contact an authorised service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to ens...

Page 3: ...o earthing may cause electric shock It may cause fire and electric shock It may cause fire It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It contains contaminants and could make you sick It may cause fire and electric shock It may cause electric shock or fire This could d...

Page 4: ...ner to preserve precision devices food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the unit for a long time If water enters the unit turn the unit off and disconnect the power contact a qualified service technician It may cause failure of appliance or acci...

Page 5: ...e indicator illuminates when TIMER is set ON PRE DEF Indicator For cooling heating model only The air conditioner starts defrosting automa tically if outdoor unit frosts in heating operating At this time PRE DEF Indicator illuminates AUTO indicator This indicator flashes when the air conditioner is in AUTO operation ECON indicator This indicator illuminates while the air conditioner is in economic...

Page 6: ... h Models For 16000 21000Btu h Models Open and lift the front panel up to an angle until it remains fixed with a clicking sound Push the AUTO button and the airconditioner will run in AUTOmode Close the panel firmly to its original position The COOL mode on the control board is only provided for testing purposes NOTE 1 3 2 Mode Cooling operation Heating operation Drying operation Temperature 1 If ...

Page 7: ...ght depending on model end of the air outlet to the desired position To automatically swing the air flow direction up down Perform this function while the air conditioner is in operation Press the SWING button on the remote controller To stop the function press the SWING button again Press AIR DIRECTION button to lock louver in desired position 5 The AIR DIRECTION and SWING buttons will be disable...

Page 8: ...ed on the difference between the set temperature and the actual room temperature The temperature is regulated while dehumidifying by repeating turning on and off of the cooling operation or fan only The fan speed indicator will display AUTO and low speed will be used Cooling Cooling Time DRYING operation Room temperature set temperature Cooling Fan only Fan only HOW THE AIR CONDITIONER WORKS To ac...

Page 9: ...RNING MAINTENANCE Filter Handle Thinner 7 Use a dry cloth to wipe the indoor unit and remote controller A cloth dampened with cold water may be used on the indoor unit if it is very dirty The front panel of the indoor unit can be removed and cleaned with water Then wipe it with a dry cloth Do not use a chemically treated cloth or duster to clean the unit Do not use benzine thinner polishing powder...

Page 10: ...the filter Injuries can occur when handling sharp metal edges Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock When cleaning the unit first make sure that the power and circuit breaker are turned off Air freshening filter Air freshening filter 4 Remove the air freshening filter from its support frame The installati...

Page 11: ...h relative humidity A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting 3 Low noise of the air conditioner You may hear a low hissing sound when the compressor is running or has just stopped running This sound is the sound of the refrigerant flowing or coming to a stop You can also hear a low squeak s...

Page 12: ...temperature If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device 9 Auto restart function Power failure during operation will stop the unit completely For the unit without Auto restart feature when the power restores the OPERATION indicator on the indoor unit starts flashing To restart the operation push the ON OFF button on the rem...

Page 13: ...Battery in Remote controller may have been exhausted The time you have set with timer is incorrect Wait for power to be restored Check that plug is securely in wall receptacle Replace the fuse Replace the battery Wait or cancel timer setting Set temperature correctly For detailed method please refer to Using remote control section Clean the air filter Close the doors or windows Clear obstructions ...

Page 14: ......

Reviews: