INSTALLATION

INSTRUCTIONS

This installation instruction is for 73ACA051T, 
73ACA051B, 73ACA061T, 73ACA081T, and 
73ACA101P air-conditioning units. Read entire
installation instructions before proceeding with
installation.

REQUIRED TOOLS

• Phillips screwdriver
• pencil
• level
• measuring  tape
• drill

1

/

8

 and 

1

/

4

-in. drill bits

INSTALLATION

WIRING

The air conditioner is powered by plugging it into a 
compatible wall outlet. The electrical outlet MUST 
match the plug on the unit power cord. The unit name-
plate contains unit electrical data, unit ratings, and 
identification numbers. Do not use a plug adapter or an 
extension cord.

Check available power supply and resolve any wiring 
problems before installing and operating the air condi-
tioner. If wiring is required, all wiring must comply 
with all local and national electrical codes. All wiring 
must be installed by a qualified electrician. If you have 
any questions regarding the unit electrical data or wir-
ing, consult a qualified electrician before installation.

For your safety, this air conditioner is grounded 
through the power cord plug when plugged into a 
matching wall outlet.

WINDOW INSTALLATION

To install the room air conditioner in a window,
perform the following procedure.

1. Check contents of hardware kit. See Table 1. Make 

sure all the items are in the plastic bag.

2. Determine which window will be used for installa-

tion. Make sure there is adequate clearance on the 
inside and outside of the window. Ensure that the 
power cord will reach the available socket without 
an extension cord. A double-hung window type 
must be used for the installation location.

TABLE 1 — HARDWARE CONTENTS

Electrical shock can cause injury or death. Do not 
install unit or remove front grille with the power 
cord plugged in. Be sure unit is unplugged before 
performing any installation or maintenance.

Electrical shock can cause injury or death. Do not, 
under any circumstances, cut, remove, or bypass the 
grounding prong on the power plug.

ITEM

QTY

3

/

4

-in. locking screws

frame/sill

2

3

/

4

-in. screw sash

safety bracket 

1

Sash safety bracket

1

1

/

2

-in. locking screws

frame/sash

2

The French section follows the English section in this manual.

Les instructions en français suivent celles en anglais.

The Spanish section follows the French section in this manual.

La sección en español aparece después de la sección en francés en 

este manual.

Summary of Contents for 73ACA051B

Page 1: ... ing consult a qualified electrician before installation For your safety this air conditioner is grounded through the power cord plug when plugged into a matching wall outlet WINDOW INSTALLATION To install the room air conditioner in a window perform the following procedure 1 Check contents of hardware kit See Table 1 Make sure all the items are in the plastic bag 2 Determine which window will be ...

Page 2: ...re proceeding 5 Place the air conditioner on floor table bench or other flat working surface Locate expanding side panels There are left and right panels 6 Holding the expanding side panel in one hand gently pull the accordion center piece back to free it from the top and bottom guide rails See Fig 2 7 Slide the end of the accordion center of the side panel into the slots on the unit cabinet See F...

Page 3: ...vided in the ends of each wing panel which are used to secure the panels to the window With the wing panels expanded mark the drilling locations on the sides of the window frame and sill through the holes in the panels See Fig 7 13 Drill the holes marked in Step 12 with 1 8 in drill bit With the side panels expanded secure the wing panels to sill with two 3 4 in locking screws provided one each si...

Page 4: ... lower than the win dow sill If the storm window frame is less than 1 2 in below the window sill then a mounting board will need to be added to raise the height of the window sill See Fig 12 The board will need to be provided and cut by the installer 1 The length of wood should be a minimum of 11 2 in wide and should run the length of the win dow The thickness of the board is dependent on the heig...

Page 5: ...he windows 4 Remove sash safety bracket and screw 5 Remove side panel screws 2 each side that are securing the side panels to the window 6 Keeping a firm grip on the air conditioner raise the sash Tilt the air conditioner back carefully to allow any condensate in the air conditioner cabi net to drain Remove the unit from the window 7 Store all parts with the air conditioner After side panel screws...

Page 6: ......

Page 7: ......

Page 8: ...scontinue or change at any time specifications or designs without notice and without incurring obligations PC 131 Catalog No 537 338 Printed in U S A Form 73ACA 1SI Pg 8 1 03A 10 02 Replaces New Book 1 4 Tab 8a 10a Copyright 2002 Carrier Corporation ...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ......

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ......

Reviews: