7–15
T-365
Figure 7.12 Condenser Fan Position
19.Use Loctite “H” on the fan set screws, and tighten.
20.Refit left and right infill panels.
21.Refit the condenser fan grille, ensuring the grille is properly centered around the condenser fan.
22.Evacuate the entire unit, refer to
23.Recharge the unit with the charge shown on the unit serial plate, refer to
. It is important for
proper unit operation that the charge is weighed into the unit.
7.11 CONDENSER FAN AND FAN MOTOR
The condenser fan rotates counter-clockwise (viewed from front of unit). The fan pulls air through the condenser
coil, and discharges the air horizontally through the front of the unit.
7.11.1
Condenser Fan Motor Remove/Replace
WARNING
!
Do not remove the condenser fan grille before turning power OFF and disconnecting the power
plug.
1. Remove the condenser fan grille, retain all bolts and washers for reuse.
2. Remove the condenser fan by loosening the two set screws.
3. Disconnect the condenser fan motor wiring.
CAUTION
!
Take necessary steps (place plywood over coil or use sling on motor) to prevent motor from
falling into condenser coil.
37mm (1.5”)
Fan
Shroud
Summary of Contents for 69NT40-561-300
Page 2: ......
Page 4: ......
Page 10: ......
Page 14: ......
Page 22: ......
Page 34: ......
Page 108: ......
Page 116: ......
Page 164: ...T 365 8 2 Figure 8 2 Unit Wiring Diagram Based on Drawing 62ï11755 ...
Page 165: ...8 3 T 365 Figure 8 3 Wiring Diagram Based on Drawing 62ï11755 ...
Page 166: ...T 365 8 4 Figure 8 4 Wiring Diagram Based on Drawing 62ï11755 ...
Page 168: ......
Page 172: ......