4–45
T-359
Table 4–8 DataCORDER Function Code Assignments
NOTE
Inapplicable Functions Display “-----”
To Access: Press ALT. MODE key
CODE #
TITLE
DESCRIPTION
dC1
Recorder Supply
Temperature
Current reading of the supply recorder sensor.
dC2
Recorder Return
Temperature
Current reading of the return recorder sensor.
dC3-5
USDA 1,2,3
Temperatures
Current readings of the three USDA probes.
dC6-13
Network Data
Points 1-8
Current values of the network data points (as configured). Data point 1 (Code
6) is generally the humidity sensor and its value is obtained from the controller
once every minute.
dC14
Cargo Probe 4
Temperature
Current reading of the cargo probe #4.
dC15-19
Future Expansion
These codes are for future expansion, and are not in use at this time.
dC20-24
Temperature Sen-
sors 1-5 Calibration
Current calibration offset values for each of the five probes: supply, return,
USDA #1, #2, and #3. These values are entered via the interrogation program.
dC25
Future Expansion
This code is for future expansion, and is not in use at this time.
dC26,27
S/N, Left 4, Right 4
The DataCORDER serial number consists of eight characters. Function
code dC26 contains the first four characters. Function code dC27 contains the
last four characters. (This serial number is the same as the controller
serial number.)
dC28
Minimum Days Left
An approximation of the number of logging days remaining until the Data
CORDER starts to overwrite the existing data.
dC29
Days Stored
Number of days of data that are currently stored in the DataCORDER.
dC30
Date of Last Trip start
The date when a Trip Start was initiated by the user. In addition, if the system
goes without power for seven continuous days or longer, a trip start will auto-
matically be generated on the next AC power up. Press and hold “ENTER” key
for five seconds to initiate a “Trip Start.”
dC31
Battery Test
Shows the current status of the optional battery pack.
PASS
: Battery pack is fully charged.
FAIL
: Battery pack voltage is low.
dC32
Time: Hour, Minute
Current time on the real time clock (RTC) in the DataCORDER.
dC33
Date: Month, Day
Current date (month and day) on the RTC in the DataCORDER.
dC34
Date: Year
Current year on the RTC in the DataCORDER.
dC35
Cargo Probe 4
Calibration
Current calibration value for the Cargo Probe. This value is an input via the in-
terrogation program.
Summary of Contents for 69NT40-561-019
Page 2: ......
Page 4: ......
Page 74: ......
Page 127: ...8 3 T 359 Figure 8 2 SCHEMATIC DIAGRAM Evergreen Unit Configuration ...
Page 128: ...T 359 8 4 Figure 8 3 UNIT WIRING DIAGRAM Evergreen Unit Configuration Sheet 1 of 2 ...
Page 129: ...8 5 T 359 Figure 8 4 UNIT WIRING DIAGRAM Evergreen Unit Configuration Sheet 2 of 2 ...
Page 130: ......
Page 134: ......
Page 135: ......