2–1
T-359
SECTION 2
INTRODUCTION
2.1
INTRODUCTION
The Carrier Transicold model 69NT40-561-019 series units are of lightweight aluminum frame construction,
designed to fit in the front of a container and serve as the container's front wall. They are one piece, self-contained,
all electric units, which include cooling and heating systems to provide precise temperature control.
The units are supplied with a complete charge of refrigerant R-134a and compressor lubricating oil, and are ready
for operation upon installation. Forklift pockets are provided for unit installation and removal.
The base unit operates on nominal 380/460 volt, 3-phase, 50/60 hertz (Hz) power. Power for the control system is
provided by a transformer which steps the supply power down to 18 and 24 volts, single phase.
The controller is a Carrier Transicold Micro-Link 3 microprocessor. The controller will operate automatically to select
cooling, holding or heating as required to maintain the desired set point temperature within very close limits. The unit
may also be equipped with an electronic temperature recorder. The controller has a keypad and display for viewing or
changing operating parameters. The display is also equipped with lights to indicate various modes of operation.
2.2
CONFIGURATION IDENTIFICATION
Unit identification information is provided on a plate located to the left of the receiver on the back wall of the con-
denser section. The plate provides the unit model number, the unit serial number and the unit parts identification
number (PID). The model number identifies the overall unit configuration, while the PID number provides informa-
tion on specific optional equipment, factory provisioned to allow for field installation of optional equipment and dif-
ferences in detailed parts.
2.3
FEATURE DESCRIPTIONS
2.3.1
Control Box
Units are equipped with an aluminum control box.
2.3.2
Temperature Readout
The unit is fitted with suction and discharge temperature sensors. The sensor readings may be viewed on the con-
troller display.
2.3.3
Pressure Readout
The unit is fitted with evaporator and discharge transducers. The transducer readings may be viewed on the con-
troller display.
2.3.4
Compressor
The unit is fitted with a scroll compressor equipped with suction and discharge service connections.
2.3.5
Condenser Coil
The unit is fitted with a four-row condenser coil using 7mm tubing.
2.3.6
Evaporator
Evaporator section is equipped with an electronic expansion valve (EEV).
2.3.7
Evaporator Fan Operation
Units are equipped with three-phase evaporator fan motors. Opening of an evaporator fan internal protector will
shut down the unit.
2.3.8
Plate Set
Each unit is equipped with a tethered set of wiring schematics and wiring diagram plates. The plate sets are
ordered using a seven-digit base part number and a two-digit dash number.
2.4
OPTION DESCRIPTIONS
Various options may be factory or field equipped to the base unit. These options are listed in the tables and
described in the following sub-paragraphs.
2.4.1
Battery
The refrigeration controller may be fitted with standard replaceable batteries or a rechargeable battery pack.
Rechargeable battery packs may be fitted in the standard location or in a secure location.
Summary of Contents for 69NT40-561-019
Page 2: ......
Page 4: ......
Page 74: ......
Page 127: ...8 3 T 359 Figure 8 2 SCHEMATIC DIAGRAM Evergreen Unit Configuration ...
Page 128: ...T 359 8 4 Figure 8 3 UNIT WIRING DIAGRAM Evergreen Unit Configuration Sheet 1 of 2 ...
Page 129: ...8 5 T 359 Figure 8 4 UNIT WIRING DIAGRAM Evergreen Unit Configuration Sheet 2 of 2 ...
Page 130: ......
Page 134: ......
Page 135: ......