40MPHA-03SM Specifications subject to change without notice.
3
SPECIFICATIONS
Table 2 — Specifications
*Performance may vary based on the compatible outdoor units. See respective pages for performance data.
SYSTEM
SIZE
9
12
18
24
Indoor Model
40MPHAQ09XA3
40MPHAQ12XA3
40MPHAQ18XA3
40MPHAQ24XA3
ELECTRICAL
Voltage, Phase, Cycle
V/Ph/Hz
208/230-1-60
208/230-1-60
208/230-1-60
208/230-1-60
Power Supply
Indoor unit powered from outdoor unit
MCA
A.
0.3
0.3
0.5
0.5
CONTROLS
Wireless Remote controller
(°F/°C Convertible)
Standard
Standard
Standard
Standard
Wired Remote controller
(°F/°C Convertible)
Optional
Optional
Optional
Optional
OPERATING
RANGE
Cooling Indoor DB Min - Max
°F (°C)
62~90 (17~32)
62~90 (17~32)
62~90 (17~32)
62~90 (17~32)
Heating Indoor DB Min - Max
°F (°C)
32~86 (0~30)
32~86 (0~30)
32~86 (0~30)
32~86 (0~30)
PIPING
Pipe Connection Size - Liquid
in (mm)
1/4 (6.35)
1/4 (6.35)
3/8” (9.52)
3/8” (9.52)
Pipe Connection Size - Suction
in (mm)
3/8 (9.52)
1/2 (12.7)
5/8” (15.9)
5/8” (15.9)
INDOOR COIL
Face Area (sq. ft.)
Sq. Ft.
2.2
2.2
3.9
3.9
No. Rows
4
4
3
3
Fins per inch
21
21
21
21
Circuits
5
5
7
7
INDOOR
Unit Width
in (mm)
35.2 (895)
35.2 (895)
49.57 (1259)
49.57 (1259)
Unit Height
in (mm)
11.7 (298)
11.7 (298)
14.25 (362)
14.25 (362)
Unit Depth
in (mm)
9.8 (248)
9.8 (248)
11.10 (282)
11.10 (282)
Net Weight
lbs (kg)
37.48 (17)
37.48 (17)
43.4 (19.7)
43.4 (19.7)
Number of Fan Speeds
4
4
4
4
Airflow (lowest to highest)
CFM
144/245/295/345
168/252/306/357
261/389/528/926
359/470/583/926
Sound Pressure (lowest to highest)
dB(A)
29/35.5/41.5/45.6
29/35.5/41.5/46.8 35.1/40.8/46.1/55.9 36.1/43.3/46.4/56.5
Air throw Data
ft (m)
21.98 (6.7)
22.97 (7)
28.80 (8.7)
31.66 (9.65)
Moisture removal
Pint/h
(L/h)
2.11 (1.0)
2.53 (1.2)
3.8 (1.8)
5.0 (2.39)
Field Drain Pipe Size O.D.
in (mm)
1 (25.4)
1 (25.4)
1 (25.4)
1 (25.4)