Specifications subject to change without notice. SG-38MPRA-02
CLEARANCES
Fig. 3 — Clearances
Table 4 — Clearances
NOTE: The outdoor unit must be mounted at least 2in (50mm) above the maximum anticipated snow depth.
Fig. 4 —Clearances for multiple units
A
D
B
Air outlet
Air inlet
C
E
UNIT
MINIMUM VALUE IN. (MM)
A
24 (609)
B
24 (609)
C
24 (609)
D
4 (101)
E
4 (101)
118in (300cm) or more
19in (48cm) or more
on a multiple parallel
unit arrangement
4in (10cm) or more on
a single parallel unit
arrangement
24in (60cm)
or more
59in (150cm)
or more on a
multiple parallel
unit arrangement
24in (61cm) or more
on a single parallel
unit arrangement
9.8in (25cm)
or more for
24in (61cm) or
more is
recommended
for service
9.8in (25cm)
24in (61cm)
or more is
recommended
for service