11.4 - Fans
Each fan motor assembly is equipped with a high-performance impeller made from recyclable composite material.
The motors are three-phase, with lifetime lubricated bearings and class F insulation (IP55 level).
When option 12 is not selected, the pressure available at the fan outlet is zero.
According to regulation No. 327/2011 implementing directive 2009/125/EC with regard to ecodesign requirements for fans
driven by motors with an electric input power between 125 W and 500 kW.
Product
30RB/30RQ
Option 15LS
(for 30RB/30RQ)
30RBP/30RQP
Option 12
Option 17
Overall efficiency
%
38,7
35,3
40,1
40,0
47,3
Measurement category
A
A
A
A
A
Efficiency category
Static
Static
Static
Static
Static
Target efficiency level ERP2015
N(2015) 40
N(2015) 40
N(2015) 40
N(2015) 40
N(2015) 40
Efficiency level at the optimum
efficiency point
43,3
42,1
44,6
43,1
52,2
Speed regulator
NO
NO
YES
YES
YES
Year of manufacture
See label on the unit See label on the unit See label on the unit See label on the unit See label on the unit
Fan manufacturer
Simonin
Simonin
Simonin
Simonin
Simonin
Motor manufacturer
Leroy Somer
Leroy Somer
Leroy Somer
Leroy Somer
EBM
Fan PN
00PSG002630700A 00PSG002630700A 00PSG002630700A 00PSG002630700A 00PSG002630700A
Motor PN
00PPG000558400A 00PPG000558500A 00PPG000558700A 00PPG000558600A 00PSG002696800A
Nominal motor capacity
kW
1,9
0,85
1,96
4,2
1,68
Flow rate
m
3
/s
4,22
3,1
4,22
5,31
4,24
Pressure at optimum energy
efficiency
Pa
174
96,7
174
216
174,6
Nominal Speed
rpm
949
710
948
1125
959
Specific ratio
1,002
1,002
1,002
1,002
1,002
Relevant information to facilitate the
disassembly, recycling or removal of
the product at the end of life
See the
Maintenance manual
See the
Maintenance manual
See the
Maintenance manual
See the
Maintenance manual
See the
Maintenance manual
Relevant information to minimise
impact on the environment
See the
Maintenance manual
See the
Maintenance manual
See the
Maintenance manual
See the
Maintenance manual
See the
Maintenance manual
Regulation 2019/1781 repealing regulation 640/2009 governs the requirements relating to ecodesign applicable to electric
motors and to speed regulators in accordance with directive 2009/125/EC. Our fan motor assemblies are exempt from this.
Product
30RB/30RQ
Option 15LS
(for 30RB/30RQ)
30RBP/30RQP
Option 12
Option 17
Motor type
Asynchronous
Asynchronous
Asynchronous
Asynchronous
Synchronous
Number of poles
6
8
6
6
-
Rated input frequency
Hz
50
50
50
60
50
Nominal voltage
V
400
400
400
400
400
Number of phases
3
3
3
3
3
Motor included in the scope of
application of regulation
2019/1781
NO
NO
NO
NO
NO
Justification for exemption
Article 2.1
Article 2.1
Article 2.1
Article 2.1
Article 2.1
Ambient air temperature for
which the motor is specifically
designed
°C
70
70
70
70
70
The above data for fans and motors, are mandatory as part of ecodesign regulations, and are provided for a standalone component
(not included in the cooling system).
11 - MAIN COMPONENTS OF THE UNIT AND OPERATING CHARACTERISTICS
49