BAD F3 FUSE
• ACTIVATION: Stepper Board Fuse Alarm; Feedback from Stepper Board indicates fuse is missing or
blown. Signal must be present for at least 3 seconds.
• UNIT CONTROL: Alarm only.
• RESET CONDITION: Replace or fix fuse issue.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (See Note 1 in
Section.) Operate the unit through the appropriate modes to see if any active
alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
Check Fuse F3
a. Visually check fuse. Verify correct fuse, and check fuse holder for damage, see
Replace fuse as required. Clear alarms, restart and check for repeat alarm(s).
b. Check voltage. Check voltage through the fuse, if fuse is blown, replace it.
c. Check wiring from PCM34 - SP-18 - 2SVM22. Verify there is no physical damage to harness, and
no damage, moisture, or corrosion in connectors.
05008
BAD F10 FUSE
• ACTIVATION: Output Board Fuse Alarm; Feedback from Output Board indicates fuse is missing or blown.
Signal must be present for at least 3 seconds.
• UNIT CONTROL: Shutdown and Alarm.
• RESET CONDITION: Replace or fix fuse issue.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (See Note 1 in
Section.) Operate the unit through the appropriate modes to see if any active
alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1.
Check Fuse F10
a. Visually check fuse. Verify correct fuse, and check fuse holder for damage, see
Replace fuse as required. Clear alarms, restart and check for repeat alarm(s).
b. Check voltage. Check voltage through the fuse, if fuse is blown, replace it.
c. Check wiring from PCM8 - 3MM34 - PCM9 - 3MM23. Verify there is no physical damage to
harness, and no damage, moisture, or corrosion in connectors.
2.
Check LIV
a. Visually verify there is no physical damage to harness, and no damage, moisture, or corrosion in
connectors.
b. Check for high amp draw. Refer to
for correct electrical values. Use ammeter.
Summary of Contents for VECTOR 8100
Page 2: ......
Page 4: ......
Page 12: ...62 11785 viii ...
Page 16: ...62 11640 12 ...
Page 18: ...62 11785 ...
Page 24: ...62 11785 1 6 1 3 SAFETY DECALS ...
Page 25: ...1 7 62 11785 ...
Page 26: ...62 11785 1 8 ...
Page 27: ...1 9 62 11785 ...
Page 28: ...62 11785 1 10 ...
Page 30: ...62 11785 ...
Page 50: ...62 11785 ...
Page 82: ...62 11785 ...
Page 96: ...62 11785 4 14 ...
Page 98: ...62 11785 ...
Page 129: ...5 31 62 11785 ...
Page 130: ...62 11785 5 32 ...
Page 134: ...62 11785 6 4 ...
Page 138: ...62 11785 ...
Page 230: ...62 11785 ...
Page 271: ...8 41 62 11785 ...
Page 272: ...62 11785 8 42 ...
Page 274: ...62 11785 ...
Page 286: ......
Page 287: ......
Page 288: ...62 11785 10 8 ...
Page 292: ......
Page 293: ......