CP3 version 3003
54
Calibration
When the sensors, LED indicators and display interfaces have been assigned, the next step is to calibrate all
the sensors. Please keep in mind that calibration can only take place when the carpark space is empty.
Automatic calibration
Before a calibration ( or at least the first time the sensors are calibrated), enter the distance between
sensors and floor. The distance is measured from the sensor head to the floor. Please follow the below
procedure:
Select sensor (or sensors) to be calibrated
Select “Mounting” (
Lane
or
Over the Car
) for each sensor
Select “Distance” (measure the distance vertically from sensor to floor) and insert the
distance in m for each sensor
Select “Write settings”and enter the data of the selected sensor/ sensors
When
Mounting
and
Distance
are completed, the next step is to calibrate the sensor or sensors:
Select sensor or sensors to be calibrated
Press “Start calibration” under Automatic mode