Stray radiation and immunity from disturbance
Emitted interference according to EN 61000-6-3: 2007 industrial sector
Interference voltage to wires according to EN 55022: 09-2003
Interference field power according to EN 55022: 09-2003
System perturbation according to EN 61000-3-2: 09-2006
Flicker according to EN 61000-3-3: 1955 + A1:2001 + A2:2005
Immunity to interference according to EN 61000-6-2: 2005 industrial sector
Electromagnetic fields according to EN 61000-4-3: 11-2003, ENV 50204: 03-1995
Fast transient burst according to EN 61000-4-4: 07-2005
Surge according to EN 61000-4-5: 12-2001
High-frequency tension according to EN 61000-4-6: 12-2001
Voltage interruption and voltage drop according to EN 61000-4-11: 02-2005
NOTICE!
This is a machine of type A. This machine can cause interferences in residential areas; in this case it can be
required from operator to accomplish appropriate measures and be responsible for it.
Connecting lines to external machines
All connecting lines have to be guided in shielded lines. Shielding has to be connected on both sides to the corner shell.
It is not allowed to guide lines parallel to power lines. If a parallel guiding cannot be avoided a distance of at least 0.5 m has to
be observed.
Temperature of lines between:
−15 … +80 °C.
It is only allowed to connect devices which fulfil the request 'Safety Extra Low Voltage' (SELV). These are generally devices
which are checked corresponding to EN 60950.
Installation of data lines
The data cables must be completely protected and provide with metal or metallised connector housings. Shielded cables and
connectors are necessary, in order to avoid radiant emittance and receipt of electrical disturbances.
Allowable lines
Shielded line:
4 x 2 x 0,14 mm² ( 4 x 2 x AWG 26)
6 x 2 x 0,14 mm² ( 6 x 2 x AWG 26)
12 x 2 x 0,14 mm² (12 x 2 x AWG 26)
Sending and receiving lines have to be twisted in pairs.
Maximum line length:
with interface V 24 (RS232C) - 3 m (with shielding)
with parallel interface - 3 m (with shielding)
with USB - 3 m
with Ethernet - 100 m
Air convection
To avoid inadmissible heating, free air convection has to be ensured.
Summary of Contents for Vario III 103/8 T
Page 1: ......
Page 4: ......
Page 5: ...Kurzanleitung und Hinweise zur Produktsicherheit Deutsch ...
Page 32: ......
Page 33: ...Instrucciones abreviadas y recomendaciones de seguridad Español ...
Page 60: ......
Page 61: ...Guide de référence rapide et de sécurité des produits Français ...
Page 88: ......
Page 89: ...Quick reference guide and product safety English ...
Page 116: ......
Page 117: ...Guida rapida e sicurezza del prodotto Italiano ...
Page 144: ......
Page 145: ...Guia rápida e informações sobre a segurança do produto Português ...
Page 172: ......
Page 173: ...Kısa kullanım kılavuzu ve ürün güvenliğiyle ilgili uyarılar Türkçe ...
Page 200: ......