Mechanics (Replace Components)
DPM IV
42
Service Instructions
05.19
5.12 Valve
C
D
B
E
F
G
A
Figure 25
1. Removing the print carriage (see chapter 5.10, page 38).
NOTICE!
It is not necessary to remove the print carriage for printing
systems from print length 240 mm. In this case, remove the
print unit cover at the rear to work from the back of the
device.
2. Remove the print carriage PCB (see chapter 5.11, page 40).
3. Remove the printhead (see chapter 5.1, page 27).
4. Remove the screws (F).
5. Disconnect the pneumatic tube (E).
6. Remove the hexagonal bolts (G).
7. Remove the screw (B).
8. Pull the complete bracket for valve (D) with the components
backwards until the valve (C) can be removed and replaced.
NOTICE!
Alternative to the steps 2 to 8, remove the drive motor (A) for
the transfer ribbon to replace the valve. In this case, ensure that
at reinstalling the belt tension and the toothing are set correctly.
Removing the valve
Summary of Contents for DPM IV
Page 1: ......
Page 16: ......
Page 26: ...Electronics Replace Components DPM IV 26 Service Instructions 05 19 ...
Page 60: ...Mechanics Replace Components DPM IV 60 Service Instructions 05 19 ...
Page 64: ...Cleaning DPM IV 64 Service Instructions 05 19 ...
Page 83: ...DPM IV Wiring Plans 05 19 Service Instructions 83 9 Wiring Plans 9 1 Control Unit Figure 45 ...
Page 84: ...Wiring Plans DPM IV 84 Service Instructions 05 19 9 2 Print Mechanics Left Version Figure 46 ...
Page 85: ...DPM IV Wiring Plans 05 19 Service Instructions 85 9 3 Print Mechanics Right Version Figure 47 ...
Page 86: ...Wiring Plans DPM IV 86 Service Instructions 05 19 ...
Page 90: ...Pin Assignment of Control Unit DPM IV 90 Service Instructions 05 19 ...
Page 95: ......
Page 96: ......