Adjustments, settings and alignments
Compa II series
32 Service
instructions
11.15
Figure 20
1. Load labels and transfer ribbon which extend across the entire
printing width.
2. Move the transfer ribbon deflection to the central position (3) with
the screw (2).
3. Position the plunger in such a way that the adjustment screws are
accessible through the holes of the square axis.
4. Loosen the screw (1) for the printhead bowing with a hexagonal
wrench (1.5 mm) and turn it counter clockwise until turning
becomes perceptibly easier. This should occur after a maximum
of a half a rotation.
When the label printer is prepared for adjustment, continue with the
adjustment of the printhead position (see chapter 6.6, on page 33).
Preparing the label
printer for adjustment