Technical user manual SLC
E-control
www.cargofloor.com
www.cargofloor.com
Page 36
Version 01 / July 10
th
, 2017
Malfunction
system
Concerns part
Cause
Solution
6. Switching is
difficult or goes
not at all. 3
Cylinders are fully
retracted or fully
out.
a. Threaded rod
Adjustment incorrect
Adjust correctly, attention:
determine cause. See: b. and
c.
Switching spring broken
Replace spring, attention:
determine cause. See: b. and
c..
b. Switching plunger Stroke > 12 mm. [0.5 inch] -
> threaded rod loose, spacer
loose
Screw in Threaded rod / bolt
fully.
c. Moving cross
member
Slanting caused by loose
profiles
*Replace screws and provide
them with a thread locking
product and check the rod
bearing.
d. Switching choke
Polluted
* Clean choke
7. Floor unloads
when choosing
loading and
unloading
Solenoid valve G02
loading / unloading
Interruption wiring
Interruption in coil
Activate manual override
G02 temporarily and/or repair
power supply
8. Floor loads
when choosing
loading and
unloading
Solenoid valve G02
loading / unloading
Manual override G02 is
activated
De-activate emergency
control
9. Other
malfunctions
Please contact your trailer builder or Cargo Floor B.V., keep the system number at
hand.
* Contact us for the right repair advice.
CONTACT DATA
Postal and visiting address:
Cargo Floor B.V.
Byte 14
7741 MK Coevorden
The Netherlands
Phone number:
+31 524 593 900
E-mail:
Website:
www.cargofloor.com
Order spare parts:
E-mail address:
DID number:
+31 524 593 922
After Sales (technical questions and malfunctions)
E-mail address:
DID number: +31 524 593 981 / +31 524 593 991
Coevorden, The Netherlands
© 2017 Cargo Floor B.V.
No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or
by any means, electronic, photocopying, recording or otherwise, without the prior permission of
Cargo Floor B.V.