Technical user manual SLC
General
www.cargofloor.com
www.cargofloor.com
Page 13
Version 01 / July 10
th
, 2017
CARGO FLOOR TECHNICAL SPECIFICATIONS
CF500
SLC
CF100
SLL
CF500
Power speed
CF
3 LP-2
(leak proof)
CF600
HDC
CF800
HD-6
Bore (mm [inch])
100
[3.9] 80
[3.15] 100
[4] 125
[4.9] 120
[4.7] 100 [3.9]
Piston rod diameter (mm [inch])
45
[1.77] 35
[1.38] 45 [1.77] 60 [2.35] 45
[1.8] 50
[2]
Stroke (mm [inch])
200
[8] 150
[5.9] 200
[8] 150
[5.9] 200
[8] 200
[8]
Cylinder volume ltr. [gallon]
2,82
[0.7]
1,36
[0.4]
2,82 [0.75]
3,26
[0.9]
4,2
[1.1] 5,5 [1.5]
Oil volume per cycle (ltr.
[gallon])
8,5
[2.2]
4,09
[1.1]
8,46 [2.25]
9,77
[2.6]
12,6
[3.3] 16,5 [4.4]
Pressure relief valve setting,
max. pressure (bar [psi])
225 [3,263]
175 [2,538]
225 [3,300]
150 [2,175]
205 [2973]
225 [3,300]
Strokes per minute with advised
pump capacity
13
17
21
11
8,7
6,6
Speed (mtr. / min [ft./min]) with
advised pump capacity
2,6
[8.5]
2,6
[8.5]
4,2 [13.8]
2,0
[6.6]
1,7
[5.6]
1,3
[10]
Advised pump capacity:
Flow (ltr./min [gpm]
110
[29]
70 [18.5]
180 [47.6]
130
[34]
110
[29] 110
[29]
Pressure (bar [psi])
250 [3,625]
200 [2,900]
250 [3,625]
175 [2,538]
220 [3,200] 250 [3,625]
Max. pump capacity:
Flow (ltr./min [gpm])
130 [34.5]
80
[21]
200 [52.8]
170
[45]
190
[50]
!E-Control
130 [34.5]
130 [34.5]
Pressure (bar [psi])
250 [3,625]
200 [2,900]
250 [3,625]
175 [2,538]
220 [3,200] 250 [3,625]
Speed at maximum
pump capacity
(mtr. / min. [ft./min])
3,1
[10]
2,9
[9.5]
4,7 [15.4]
2,6
[8.5]
3,0
[9.8]
!E-control
2
[6.2]
1,6
[5.2]
Solenoid/coil; 24V DC only E and B control (optional available 12 V DC)
Pressure filter type; high-pressure 10 micron (part no.
ESTIMATED UNLOADING TABLE
Specifications for a Cargo Floor CF500 drive unit with 100 mm [3.9"] bore cylinders.
Engine
Pump output
speed
*
Unloading time
13.6 mtr [45 ft] trailer
550 RPM/m [rpm]
60 l/m [15 g/min]
1.4 m/min [4.6 ft/min]
9-10 minutes
750 RPM/m [rpm]
80 l/m [21 g
/
min]
1.9 m/min [5.9 ft/min]
7-8 minutes
1000 RPM/m [rpm]
110 l/m [29 g/min]
2.6 m/min [8.5 ft/min]
5-6 minutes
These only are approximate meters per minute and should strictly be used as a reference!