WET KIT INFORMATION
This wet kit is designed to be used with most transmissions. Power Take Off (P.T.O.) specifications may
vary with some transmissions. Please check with your supplier for specific applications.
The wet kit used to power the Cargo Floor system must comply with the following specifications:
CF500
SLC
CF100
SLC
CF500
SLC
Power
Speed
CF3 LP-2 CF600 HDC
CF800
Advised pump
capacity (l/min [gpm])
110 [29]
70 [18]
180 [48]
110 [29]
110 [29]
110 [29]
Max. Pump capacity
(l/min [gpm])
130 [34]
80 [21]
200 [53]
170 [45]
190 [50]
130 [34]
Max. Pressure relieve
valve *bar [psi]
250 [3,625] 200 [2,900] 250 [3,625] 175 [2,538] 220 [3,191] 250 [3,625]
*Pressure relieve valve must have the ability to relieve the full pump flow at the maximum pressure for
the system.
PRINCIPLE WET KIT DIAGRAM