Carel PJEZ Series Quick Start Manual Download Page 1

PJEZ (PJEZ****G/H/I/L/M/N/O/P*)

 - 

electronic controller

+050004235 - rel. 1.2 - 09.07.2015

Dimensions (mm)

Panel mounting
Rear (with 2 quick-fit side brackets)

Fig. 1

Fig. 2

Description

PJEZ* (models S, Y, C) represent a range of electronic microprocessor controllers with LED display developed for 
the management of refrigerating units, display cabinets and showcases. 
• 

PJEZS*, designed for the management of static refrigerating units, no fan on the evaporator, operating at         
temperature above 0°C; 

• 

PJEZY*, designed for the management of static refrigerating units, no fan, operating at low temperatures;

• 

PJEZC*, designed for the managements of low temperature ventilated refrigerating units.

Technical specifications

power supply  

230 Vac +10 /-15% 50/60 Hz; 115 Vac +10 /-15% 50/60 Hz

rated power

3.5 VA

inputs

NTC probes 1 or 2 inputs

1 digital input

relay outputs 

30 A relay        UL: 16 A Res. 16 FLA 96 LRA - 240 Vac (FASTON tabs)

                       EN60730-1: 20(10) A 250 Vac (FASTON tabs)

                       UL: 12 A Res. 12 FLA 72 LRA - 240 Vac

                       EN60730-1: 12(10) A 250 Vac

8 A relay          UL: 8 A Res. 2 FLA 12 LRA - 240 Vac C300,

                       EN60730-1: 8(4) A NO, 6(4) A NC, 2(2) A CO - 250 Vac

5 A relay          UL: 5 A Res. 1 FLA 6 LRA - 240 Vac C300,

                       EN60730-1: 5(1) A - 250 Vac

type of probe

Std CAREL NTC 10 K

Ω

 at 25 °C

connections 

for screw terminals, cross-section of cables from 0.5 mm2 to 1.5 mm2, rated maximum 

current per terminal 12A

for FASTON tabs, cross-section of cables up to 2.5 mm2, rated maximum current per 

terminal 20A

assembly

use rear brackets

display

2 digit LED display with sign (-99 to 99) and decimal point; four status LEDs

operating conditions

-10T50 °C - humidity <90% rH non-condensing

storage conditions

-20T70 °C - humidity <90% rH non-condensing

range of measurement

-50T90 °C - resolution 0.1 °C

front panel index of protection

panel installation with IP65 type 1 gasket

case

plastic terminal, 81x26x65 mm

classification according to protection against 

electric shock

Class II when suitably integrated

environmental pollution

normal

PTI of the insulating material

250V

period of stress across the insulating parts

long

category of resistance to heat and fire

category D (UL94 – V2)

immunity against voltage

category 1

type of action and disconnection

1C relay contacts

no. of relay automatic operating cycles

100,000 operations

software class and structure

Class A

cleaning the instrument

only use neutral detergents and water

cable max. length

probes: 30m, relay: 10m

WARNING:

• 

do not run the power cable less than 3 cm from the bottom part of the device or from the probes; 

• 

the connections only use copper wires;

• 

relay not allowed to use on fluorescent lamp(neon) with phase-shift capacitors.

Table of alarms

Alarm code

LED

Description

Parameters 

involved

E0

ON

probe 1 error = control

-

E1(*)

ON

probe 2 error = defrost

[d0 = 0 / 1]

dr(*)

ON

open door alarm

Lo

ON

low temperature alarm

[AL] [Ad][A0]

HI

ON

high temperature alarm

[AH] [Ad][A0]

EE

ON

unit parameter error

-

EF

ON

operating parameter error

-

(*) 

not available for PJEZS*E*

IMPORTANT WARNINGS

The CAREL product is a state-of-the-art device, whose operation is specified in the technical documentation 
supplied with the product or can be downloaded, even prior to purchase, from the website www.carel.com.The 
customer (manufacturer, developer or installer of the final equipment) accepts all liability and risk relating to the 
configuration of the product in order to reach the expected results in relation to the specific final installation and/
or equipment. The failure to complete such phase, which is required/indicated in the user manual, may cause 
the final product to malfunction; CAREL accepts no liability in such cases. The customer must use the product 
only in the manner described in the documentation relating to the product. The liability of CAREL in relation to its 
products is specified in the CAREL general contract conditions, available on the website www.carel.com and/or by 
specific agreements with customers.

PJEZS*

9 10 11

8

DI 

NTC

PROBES

N

1   2   3   4   5

6   7

L

-10T50

DEF. T.

DEF. T.

DI 

NTC

PROBES

JST CONNECTOR

AMB. T.

AMB. T.

PJEZ(C,Y)*

1   2   3   4   5

6   7

L
N

-10T50

or

or

Electrical connections

Fig. 3

Disposal of the product

The appliance (or the product) must be disposed of 
separately in accordance with the local waste disposal 
legislation in force.

Safety standards:

Installation precautions:
• 

the connection cables must guarantee insulation up to 
90 °C;

• 

ensure a space of at least 10 mm between the case and 
the nearby conductive parts;

• 

digital and analogue input connections less than 30m 
away; adopt suitable measures for separating the cables 
so as to ensure compliance with the immunity standards; 
Secure the connection cables of the outputs so as to avoid 
contact with very low voltage parts.

NOTE: PJEZS*E* only support one NTC probe.