IROPZ48500:
RS485 serial board interface option for IR33/powercompact
cod. +050003880 - rel. 1.1 - 07/11/2008
CAREL S.p.A.
Via dell’Industria, 11 - 35020 Brugine - Padova (Italy)
Tel. (+39) 0499716611 – Fax (+39) 0499716600
http://www.carel.com – e-mail: [email protected]
CAREL si riserva la possibilità di apportare modifiche o cambiamenti ai propri prodotti senza alcun preavviso.
CAREL reserves the right to modify the features of its products without prior notice.
cod. +050003880 - rel. 1.1 - 07/11/2008
Thank you for your choice. We trust you will be satisfied with your
purchase.
The RS485 serial option is used to connect CAREL compatible
controllers to a supervisory network via a standard RS485 serial line. The
input normally used for the programming key is also used for this pur-
pose, having the dual function of key input / serial communication port
(only on controllers where fitted).
Assembly
Connect the RS485 option to the CAREL controllers (at the key serial
input) using the 4-wire cable; depending on the neccessity use a cable
75mm or 220mm lenght.
Make the connection to the supervisory network, as shown in Fig. 2.
The serial line should be terminated with a 1/4 W 120
Ω
resistor between
terminals TxRx+ and TxRx-.
Refer to the documents on the corresponding controllers for the
setting of the serial address and the maximum number of connections.
WARNING:
• Check the technical documents on the corresponding controllers for
the connection of the power supply, so as to avoid damaging the
instrument.
• Securely fasten the option so as to prevent it from being
disconnected. It must be fixed inside the same device as the
controller.
• Connect the wiring with the power supply disconnected.
• Keep the serial option cables separate from the power cables (relay
and power supply outputs).
Technical specifications
Power supply
5 V ± 10%
(supplied by the controller)
Storage conditions
temperature –10T70°C;
humidity 0% to 80% r.H., non-cond.
Operating conditions
temperature –10T65°C;
humidity 20% to 80% r.H., non-cond.
Index of protection
IP20
Environmental pollution
normal
Protection against
To be incorporated in class I or
electric shock
II devices.
The insulation depends on the
controller the option is connected to.
Category of resistance
D (UL94 HB)
to heat and fire
PTI of the insulating
250 V
materials
3-way terminal
cross-section 1.5 mm
2
Cables to be used
twisted pair plus shield
Serial port
not optically-isolated
Speed 19200
baud
Maximum distance from
1 km
the supervisor
24
31
54
85 / 230
75 / 220
5
5
GND
T+
T-
GND
T+
T-
GN
D
T+
T-
PC485KIT00
1..
powercompact
IR33
...n
GND
USB-485
Converter
CVSTDUMOR0
T+
T -
USB
SERIAL PORT
Dimensions
Fig. 1
Connection example
Fig. 2