"humiFog direct" +0300073EN rel. 1.0 - 31.03.2017
Alarm
Code Cause
Possible solution
Reset
Alarm relay
Action
Wireless p. 7 offline
ALP14 No communication
with probe 7
Check:
• probe/access point binding
• battery charge
• probe signal level
Automatic
Active
Signal
Wireless p. 8 offline
ALP15 No communication
with probe 8
Check:
• probe/access point binding
• battery charge
• probe signal level
Automatic
Active
Signal
Main probe 1 offline
ALP16 No communication
with all the wireless
probes - main control
in zone 1
Check:
• probe connections
• probe/access point binding
• access point power supply
Automatic
Active
Signal
Limit probe 1 offline
ALP17 No communication
with all the wireless
probes - limit control
in zone 1
Check:
• probe connections
• probe/access point binding
• access point power supply
Automatic
Active
Main probe 2 offline
ALP18 No communication
with all the wireless
probes - main control
in zone 2
Check:
• probe connections
• probe/access point binding
• access point power supply
Automatic
Active
Signal
Limit probe 2 offline
ALP19 No communication
with all the wireless
probes - limit control
in zone 2
Check:
• probe connections
• probe/access point binding
• access point power supply
Automatic
Active
Signal
Unit 1 alarm
ALN01 Alarm on unit no. 1 in
network
Only if network function is active
Carry out the checks based on the alarm displayed on
the unit in question
Automatic
Active
Signal
Unit 2 alarm
ALN02 Alarm on unit no. 2 in
network
Only if network function is active
Carry out the checks based on the alarm displayed on
the unit in question
Automatic
Active
Signal
Unit 3 alarm
ALN03 Alarm on unit no. 3 in
network
Only if network function is active
Carry out the checks based on the alarm displayed on
the unit in question
Automatic
Active
Signal
Unit 4 alarm
ALN04 Alarm on unit no. 4 in
network
Only if network function is active
Carry out the checks based on the alarm displayed on
the unit in question
Automatic
Active
Signal
High bypass temp.
WRA12 Water temperature in
bypass > 50°C
Possible extended recirculation of water through the
bypass. Check:
• that the humidification capacity set on screen Dc18 is
equal to the no. of nozzles x capacity of each nozzle;
• that the zone can deliver a flow-rate of water ≥ the
minimum flow-rate supplied by the pump;
• that the NTC probe is connected to terminals J5.2-J5.3
-
Warning
Low pressure
-
Pressure measured by
probe HPS < 60 bars
with pump running
Possible small water leaks at the outlet, check tightness
of the hose fittings and make sure there are no leaks
from the drain solenoid valves DR1 and DR2.
Check that the pump is able to deliver the flow-rate
required to satisfy the load provided by the nozzles.
-
Inactive
Warning
Tab. 10.a