Carel Easy PJEZS Series Manual Download Page 1

CAREL  

 SERIES REFRIGERATION CONTROL – FIELD SUPPORT GUIDE 

1.  Overview of the Easy control’s display and buttons: 

 

2.  

Wiring the control’s connections correctly: 

 Carel controls come in a wide variety of different configurations, often 

customized for the OEM appliance manufacturer. A label found on top of the control will show a wiring guide and electrical 
specifications for the specific model. When replacing the control, 

DO NOT ASSUME

  that the numbered terminals will always serve 

the same function as the previous control installed. Carefully check all connections according to the labels / symbols shown 
underneath each numbered contact.

 

Common Configurations:  PJEZS* Models – Medium Temp 

 

 

 

PJEZC* Models – Low Temp

 

                                

              

 

Carefully note the following connections available on your model, and connect the wires accordingly. 

Temperature probe input(s) 

 

Control probe (AMB) and optional defrost probe (DEF), with a common 

Digital input 

 

Configurable input for alarm, defrost, curtain etc. (Parameter A4) 

Compressor output 

 

Contact points may vary across different control models 

Fan output 

 

Contact points may vary across different control models 

Defrost output 

 

Contact points may vary across different control models 

Auxiliary output 

 

Contact points may vary across different control models 

Line voltage to outputs 

Typically isolated from supply voltage, requiring its own connection 

Supply voltage  

L/N 

Line and neutral supply wires, most commonly points 6 and 7 

 

3.  

Viewing and changing the set point:

 

 Press and hold the red SET button for 1 second to view current set point, 

and release immediately after it is displayed. (Display may flash, indicating the value can be changed.) 
Press UP and DOWN arrows to change value and press SET again to store new value.

 

Reviews: