Site-specific options
Pyxis MedStation 4000 System Console User Guide
115
8. If applicable, do the following:
•
Discharge if inactive
(Patients maintenance)—Enter the number of days
after which patients without transactions are discharged from the facility.
Set this value greater than or equal to the activities hold time set at the
Devices dialog box.
•
Inactivity notification
(Users maintenance)—Enter the number of days
after which a service message is logged for users who have not performed
any transactions. To review a list of service messages, run the Service
Messages report. If a service message is listed that indicates a specific
number of users have been inactive for a specific number of days, you can
then run the Users report using the User Last Access parameter to produce
a detailed list of inactive users. (For more information, refer to the
Pyxis
MedStation 4000 System Console Reports Booklet
.)
9. To save your changes, click
OK
and then click
Save
.
10. In the confirmation message that appears, click
OK
.
Running a maintenance task
Rather than waiting for the scheduled time for a particular maintenance task, you
can choose to run it immediately.
To run a maintenance task
1. Select
System Setup > Site Specific Options
.
2. In the Site Information dialog box, click the
Maintenance
tab.
3. Select the maintenance task.
4. Click
Run Maintenance Now
.
5. In the Run Maintenance Now dialog box, select the maintenance tasks and
click
Go
.
Customizing the console name
The Sources page allows you to provide an alias for the console. This alias name
is the name that appears in selection lists or reports.
NOTE
Do not change the Maintenance options without assistance from a CareFusion
representative.
Summary of Contents for Pyxis MedStation 4000
Page 26: ...Chapter 2 Console Basics 16 Pyxis MedStation 4000 System Console User Guide...
Page 146: ...Chapter 3 Setting Up the System 136 Pyxis MedStation 4000 System Console User Guide...
Page 190: ...Chapter 6 Reports 180 Pyxis MedStation 4000 System Console User Guide...
Page 220: ...Appendix D Cerner 210 Pyxis MedStation 4000 System Console User Guide...
Page 236: ...Glossary 226 Pyxis MedStation 4000 System Console User Guide...
Page 246: ...Index 236 Pyxis MedStation 4000 System Console User Guide...