Alaris® GW Volumetric Pump
(with Set Detection Mode disabled)
Directions For Useen
Page 1: ...s Alaris GW Volumetric Pump with Set Detection Mode disabled Directions For Use en...
Page 2: ...d 10 Starting the Infusion 14 Secondary Piggyback Infusions 15 Basic Features 16 User Selectable Options 19 Configurable Options Sheet 20 Alarms 21 Warnings 22 Flow Sensor Operation 23 Compatible Dedi...
Page 3: ...warranties concerning the adequacy and safe performance of any non dedicated infusion sets as it relates to the operation of the pump and the accuracy of the infusion In no event shall CareFusion be l...
Page 4: ...oss references made to another section of this manual Italics Used to refer to other documents or manuals and also used for emphasis A Important Information Wherever this symbol is shown an Important...
Page 5: ...the Infusion set Door Latch Press outer latch to open the pump door Flow Stop Mechanism When activated the mechanism will stop fluid flow Flow Direction Label Bevel Releases the flow stop mechanism l...
Page 6: ...Confirms the rate during an infusion titration hf CHEVRON keys Increases or decreases the infusion rate TIME limit and VTBI Press and hold to increase the selection speed Used to adjust user selectabl...
Page 7: ...inst vertically falling drops of water r Alternating Current s Device complies with the requirements of Council Directive 93 42 EEC as amended by 2007 47 EC T Date of Manufacture t Manufacturer Connec...
Page 8: ...p is a positive pressure pump which should use Infusion sets fitted with Luer lock fittings or equivalent locking connectors To infuse from a burette close the roller clamp above the burette and open...
Page 9: ...in conjunction with other pumps or devices requiring vascular access extra care is advised Adverse delivery of medication or fluids can be caused by the substantial variation in pressures created wit...
Page 10: ...the pump will duly stop the infusion and alert the user by generating a combination of visual and audible alarms Should any encountered alarm condition persist even after user intervention it is reco...
Page 11: ...fusion sets with the Set Detection Mode disabled are advised to assess performance of the pump and infusion set combination prior to clinical use If adequate performance is not achieved then the Alari...
Page 12: ...when not in use Docking Station Workstation or Equipment Rail Installation Release lever Rectangular bar Rotating cam The rotating cam can be fitted to the rectangular bar on the Docking Station Work...
Page 13: ...sion sets ensure a separation of at least 30cm is maintained between the pump and the upper Y site 1 Close the in line clamp on the Infusion set Press the door latch to open the tubing cover door 2 Re...
Page 14: ...the IV line according to hospital protocol 5 Attach the set to the patient or other Infusion set 6 Start the infusion see Starting the Infusion A Use the prime function to fill the Infusion sets befo...
Page 15: ...equired 6 Press d button to start infusing Standard Mode with VTBI Time Infusion on 1 Enter VTBI using the f h keys 2 Press e button once to confirm the VTBI 3 Enter TIME using the f h keys 4 Press e...
Page 16: ...e clamp on the secondary set 11 Press e button to scroll further or press d button to start the secondary infusion 12 Ensure the SEC Secondary indicator is lit Note The infusion rate will automaticall...
Page 17: ...g between infusion parameters using the e button Muting the alarm using the c button Pausing resuming the infusion using the d button Optimising the Pumps Performance Pump performance may be optimised...
Page 18: ...h the Directions for Use Carefully read the Directions For Use supplied with the Infusion set prior to use SmartSite Needle Free System Instructions SmartSite Needle Free Valve is designed to permit s...
Page 19: ...e in line clamp 7 Press the b button once and E will be displayed 8 Press and hold the b button while E is still displayed until there is no visible air in the IV line according to hospital protocol 9...
Page 20: ...turn to G or set up mode or next option Setting the Alarm Volume 1 Press e button until tonE is displayed 2 Select an alarm volume between 1 Low and 7 High using the h f keys 3 Press e button to retur...
Page 21: ...nications 1 250 1 Flow Sensor Connection Mode AUTO On On Set up of current time and date 00 00 to 23 59 01 01 00 to 31 12 99 N A Language selection EnGL FrAn dEut ItAL ESPA SE nEd EnGL IrDA Communicat...
Page 22: ...ure that the infusion set tubing is properly loaded in the pumping channel following the flow direction label Ensure that ample fluid is in the fluid container Check for blockage occlusion in infusion...
Page 23: ...s has been administered D Finished pre set volume to be infused Pump will infuse at the keep vein open rate until the d button is pressed Refer to KVO Rate section of this DFU E The pump is priming th...
Page 24: ...Off NO MANDATORY Only CareFusion dedicated infusion sets can be used in this mode CareFusion does not recommend the use of other manufacturers Infusion Sets Model 180 Flow Sensor Handles Drip chamber...
Page 25: ...5 m filter in drip chamber anti siphon valve 220 cm 273 002 Infusion set with 15 m filter in drip chamber 1 Y site and anti siphon valve 220 cm 273 003 Infusion set with 15 m filter in drip chamber 2...
Page 26: ...nti siphon valve 220 cm Opaque Sets 273 011 Opaque PVC infusion set with anti siphon valve and pump segment with 15 m filter in drip chamber 235 cm Low Sorbing Sets 273 053 Low Sorbing PVC infusion se...
Page 27: ...lter and one SmartSite Valve Y port Rotating male Luer lock approx 51 cm 20350E 0006 Extension set with 0 2 m filter and one SmartSite Valve Y port Rotating male Luer lock approx 51 cm Low Sorbing Pol...
Page 28: ...1000DF00440 Issue 3 27 38 Alaris GW Volumetric Pumps Associated Products Associated Products The Alaris Gateway Workstation The Alaris DS Docking Station...
Page 29: ...to the AC power supply whether the pump is in use or not The battery is automatically charged during AC operation and whenever the pump is connected to the AC power supply and the AC power indicator...
Page 30: ...essive cleaning agents as these may damage the exterior surface of the pump Do not steam autoclave ethylene oxide sterilise or immerse this pump in any fluid Storing the pump If the pump is to be stor...
Page 31: ...ype 4 AC Power Supply 100 120 VAC 50 60Hz 10VA nominal 220 240 VAC 50 60Hz 10VA nominal Protection against fluid ingress IPX1 Proteted against vertically falling drops of water Dimensions 137mm w x 14...
Page 32: ...least 6 months when not powered up Minimum Occlusion Alarm Pressure 100mmHg Maximum Occlusion Alarm Pressure 1000mmHg Bolus volume generated at 25 0 ml h when the minimum occlusion alarm threshold is...
Page 33: ...with the use of non dedicated infusion sets Infusion sets not manufactured by CareFusion regardless of whether CareFusion has been advised as to the possibility of such use Notes 1 All accuracy speci...
Page 34: ...assessment for the suitability of any software used in the clinical environment to control or receive data from the pump lies with the user of the equipment This software should include detection of t...
Page 35: ...formance of the Alaris GW Volumetric Pump when used in combination with a typical dedicated infusion set The user is responsible for assessing the performance of the Alaris GW Volumetric Pump when use...
Page 36: ...ine when the infusion commences and alarms at a preset limit above the baseline pressure The pressure alarm limits are 250 350 and 500 mmHg above the baseline pressure corresponding to the low normal...
Page 37: ...with Plus Software 9002MED01 G Alaris GP Guardrails Volumetric Pump with Plus Software 80203UNS0x xx1 Alaris Gateway Workstation 1 For Workstation contact local customer services representative to obt...
Page 38: ...j 25 B 2800 Lyngby Danmark CareFusion Via Ticino 4 50019 Sesto Fiorentino Firenze Italia CareFusion Hammarbacken 4B 191 46 Sollentuna Sverige Tel 32 2 267 38 99 Tlf 45 70 20 30 74 T l 39 055 30 33 93...
Page 39: ...Page Intentionally Left Blank...
Page 40: ...ontains proprietary information of CareFusion Corporation or one of its subsidiaries and its receipt or possession does not convey any rights to reproduce its contents or to manufacture or sell any pr...