CCM3A-2216-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENTALERT.IE Silent Alert International
TEL +353 (0)1 247 9007
MOVE KEY DOWN TO SWITCH ON
Magnetic Activation
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 = System Co
de 1
2= System
Code 2
3 = System Co
de 3
4 = System Co
de 4
5 =
Audio
Monitor
ing
6 = Zone Multipl
ier (7
-12)
7 = Short
Audio
Delay
8 = Medium
Audi
o Delay
7 & 8 = Long
Audio
Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10
Mins
9 & 10 = PIR Dela
y 15 m
ins
11 = Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY DOWN TO SWITCH ON
PUSH
PUSH
1 2 3 4 5 6 7 8
Configuration switches shown with
cover removed. Do not alter these
without referring to page 2
Status light
Magne
t
Test button
Configuration
switch Cover
CCD4A-2220-EU
CARE CALL
MINI MAGNETIC
DOOR MONITOR
USE ALKALINE PP3
9 V BATTERY ONLY
Batch 06/01/14
www.silentalert.ie
Silent Alert International, IRL
Tel: +353 (0)1 247 9007
Keys 1-4 System
Channel
Key 5=10 Sec Delay
Key 6=20 Sec Delay
Keys 5+6=30 Sec Delay
Key 7 Leave ON
Key 8 Not Used
USE WITH MAGNET SUPPLIED
PP3 battery
contacts
Screw cap
Screw cap
CCD4A-2220-EU
CARE CALL
MINI MAGNETIC
DOOR MONITOR
USE ALKALINE PP3
9 V BATTERY ONLY
Batch 06/01/14
www.silentalert.ie
Silent Alert International, IRL
Tel: +353 (0)1 247 9007
Keys 1-4 System
Channel
Key 5=10 Sec Delay
Key 6=20 Sec Delay
Keys 5+6=30 Sec Delay
Key 7 Leave ON
Key 8 Not Used
USE WITH MAGNET SUPPLIED
PP3 Battery
PUSH
PUSH
The light will then will flash
green several times to show the
battery voltage.
9 flashes = 9Volts in the battery.
When a battery is first fitted the
indicator light will flash red then
green a few times then light
solid green & pause briefly.
1.
Install a 9 volt PP3 alkaline or lithium battery
making sure to observe the correct polarity.
PUSH
If the light flashes red at this
point the battery is flat
and will need to be replaced.
To repeat the battery check remove the battery, press the test
button then re-insert the battery to start the sequence again.
PUSH
2.
To test the unit press the
button on the front of the unit.
Alternatively the supplied
magnet can be used to trigger
the unit by swiping it through
the pickup area.
The monitor is activated using an internal reed
switch and a magnet.
Test Button
Magnetic
switch
pickup area
NOTE* The magnet must pass within 1cm of
the pickup area to activate the unit.
3.
Secure the Mini Monitor
to the door frame
as close as possible to the
edge of the door using the
supplied screws.
The Magnet must pass
within 1cm of the pickup
area to trigger the unit.
PUSH
P
U
S
H
4.
We recommend mounting the monitor opposite to the
door hinge. The magnet does not need to be in close proximity
to the pickup area when the door is closed as the unit is
triggered when the magnet passes through the pickup area.
The magnet needs to pass within 1cm of the pickup area as
the door is opened. It is possible to mount the monitor in a
variety of positions as shown in the diagram. Experiment to
find the best position before fixing to the door frame.
Once the optimum position has been established the magnet
should be secured to the door frame using the sticky pad or
screws provided.
P
U
S
H
Deactivating & reactivating the door monitor
PUSH
PUSH
Press and hold the test button until the light
flashes red, then release. This will
deactivate the door sensor.
Press and hold the test button until the light
flashes green, then release. This will
reactivate the door sensor.
Care
Call
Quick start guide CCD4A-2220-EU
Care Call Mini Magnetic Door Monitor
Any questions? Call us on
+353 (0)1 247 9007