![Cardinal 190 Series Installation, Technical And Operation Manual Download Page 87](http://html.mh-extra.com/html/cardinal/190-series/190-series_installation-technical-and-operation-manual_2556155087.webp)
8400-M022-O1 Rev K
Model 190 Indicator
79
TEST MODE/ DIAGNOSTICS
The Cardinal Model 190 Weight Indicator has a comprehensive diagnostic feature that can
allow it to self-diagnose a problem. After displaying the model number, software revision, and
performing a display test, the indicator will enter the diagnostics mode.
The diagnostics feature will check to ensure that the internal memory is functioning correctly,
that setup parameters (as well as other operational parameters) are within range and that the
battery (if equipped with batteries) voltage is correct for operation.
Accessing Test Mode/Diagnostics
To access the Test Mode/Diagnostics feature, with the indicator ON, press the
Fn/
key and
press the
UNITS/
key. Each test lasts about one second.
1.
The model number (190) will be displayed
2.
The software version (r #.#.#) will be displayed.
3.
All horizontal segments will turn on and then off.
4.
All vertical segments and decimal points will turn on and then off.
5.
The key status arrows will turn on and then off.
6.
Each weight mode annunciator (lb, kg, etc.) will turn on and then off.
7.
The diagnostics feature will perform an internal memory check, verify that the setup
parameters (and other operational parameters) are within range and if equipped with
batteries, that the voltage is correct for operation.
8.
SETUP=
and
PASS
will be displayed if everything passes the diagnostic check.
9.
The calibration numbers (C1 to C4) will be displayed.