8400-M022-O1 Rev K
Model 190 Indicator
68
Accumulated Weight Function
When the accumulated weight function has been enabled during setup of the indicator, the
function must be activated before it can be used. Refer to the section, Function Setup, the
FUnC
(
FUnC?
) parameter to enable the
Fn/
key Hold function.
NOTE:
If Legal-For-trade (
LFt=yes
)
has been selected in setup, the Gross weight
must return to zero before the next weighing operation to enable accumulation.
Activate Accumulated Weight Function
1.
Press and hold the
Fn/
key until the display blanks.
2.
Once the display blanks, release the
Fn/
key
3.
The display will change to show
ACCU
X, the prompt, and status of the Accumulated
Weight function.
4.
If the setting displayed is acceptable, press the
TARE
key to save it. Otherwise, use
the
Fn/
key to toggle to a new setting and press the
TARE
key to save it.
1
= Accumulated Weight Function Active
0
= Accumulated Weight Function Not Active
5.
Repeatedly press the
TARE
key to step through the remaining function prompts until
the indicator returns to the weight display.
Accumulated Weight Function Operation
During operation, the weight recorded when the
key is pressed will be added to the
accumulator. This will be indicated by
totAL
being displayed briefly after the
key
has been pressed.
1.
To display the Accumulator, simultaneously press the
UNITS/
and
TARE
keys. If
Legal-For-trade (
LFt=yes
)
is on, the gross load must be zero.
2.
The Gross accumulator weight will be shown as indicated by the alternating
G
and
A
.
3.
After a brief interval, the display will show the number of Gross weight items
accumulated, indicated by the alternating
G
and
C
.
4.
The display will alternate between showing the Gross accumulator weight and the
Gross accumulator count.
5.
Press the
TARE
key and the Net accumulator weight will be displayed, indicated by
the alternating
n
and
A
.
6.
After a brief interval, the display will show the number of Net weight items accumulated,
indicated by the alternating
N
and
C
.
7.
The display will alternate between showing the Net accumulator weight and the Net
accumulator count.
8.
Press the
TARE
key to display the Gross accumulator again.
9.
Press the
ZERO
key to clear the displayed accumulator.
10.
Press the
NET/GROSS
key to return to the normal weight display.