8400-M022-O1 Rev K
Model 190 Indicator
40
Display High Resolution Weight
IMPORTANT! The
Hires
(
Hires?
) mode requires a load of 10% of Capacity on
the scale.
Hi res
High Resolution Weight (from
SETUP
Prompt)
1.
If displaying High Resolution Weight is desired, with the
SETUP
prompt displayed,
press
UNITS/
key until the display shows the
Hires
prompt.
2.
Place a calibrated test weight on the scale and press the
TARE
key.
3.
The display will change to show the amount of the test weight in "high resolution" mode
(1/10 division), an
h
will be displayed to the right of the annunciators and the
annunciators will alternately flash off and on.
4.
Press the
Fn/
key to increase the span by 0.1 division
OR
press the
UNITS/
key to
decrease the span by 0.1 division.
5.
Press the
TARE
key to exit the Display High Resolution Weight and advance to
LoCoUt?
prompt.
Hires?
High Resolution Weight (after TARE
pressed at
FSPAN
prompt)
1.
With
Hires?
displayed, press the
TARE
key.
2.
The display will change to
no
.
3.
Place a calibrated test weight on the scale.
4.
Press the
Fn/
key to toggle to
yes
and press the
TARE
key.
5.
The display will change to show the amount of the test weight in "high resolution" mode
(1/10 division), an
h
will be displayed to the right of the annunciators and the
annunciators will alternately flash off and on.
6.
Press the
Fn/
key to increase the span by 0.1 division
OR
press the
UNITS/
key to
decrease the span by 0.1 division.
7.
Press the
TARE
key to exit the Display High Resolution Weight and advance to the
LoCoUt?
prompt.