17
Manually cancelling a pair of photoelectric cells without the transceiver device (fig. 3)
1. On the stationary unit press and hold down the button
P2
until the stationary unit sounds a ‘beep’: you
have now entered the cancellation mode and the led
L1
will flash quickly.
2. Press and hold down the button
P1
until the stationary transceiver interface sounds a single beep: you
have now entered manual cancellation mode and led
L1
will flash very quickly.
3. The leds
L3
and
L4
will flash to indicate the currently selected safety device. You can cycle between the
safety devices you wish to cancel by briefly pressing button
P1 .
4. Press and hold down the button
P2
until the stationary transceiver interface sounds a double ‘beep’
indicating that the selected safety device has been cancelled.
5. To quit the cancellation mode wait for
30
seconds or press the button
P1
in the stationary receiver until it
sounds an extended ‘beep’.
Completely cancelling the memory content (fig. 3)
1. Press and hold down the buttons
P1+P2
on the stationary unit for more than 5 seconds.
2. A ‘beep’ will indicate the start of the procedure and led
L1
will remain lit for the duration of the procedure.
3. Led
L1
will turn off when the cancellation procedure has terminated.
L1 indications on the receiver of the photoelectric cells
- Led continuously lit for 4 s, successful memorisation/cancellation attempt.
- Led flashes quickly for 4 s, unsuccessful memorisation/cancellation attempt.
Stationary unit LED indications
L1
flashes slowly, memorisation procedure in the stationary unit is in course;
L1
lashes quickly, cancellation procedure via radio in the stationary unit is in course;
L1
flashes very quickly, manual cancellation procedure in the stationary unit is in course;
The led will light up briefly when the status of the photoelectric cells are being checked.