2
The RED LED above the button should flash briefly to show door is
between the limit switches.
Briefly press the button once to move the door to the fully
open position.
NOTE:
If the motor runs but the door does not move and the
LED
flashes red, TURN OFF POWER. Ensure drive pin is correctly engaged in
drive tape (see
section 5
) Then restart set up sequence.
3
With the door now fully open, briefly press the
button once to close
the door for the DOWN LEARN sequence.
4
When the door is closed briefly press the
button again to open the
door for the UP LEARN sequence.
5
The LED should now show green or flashing green to confirm that
set-up has been successfully completed.
NOTE:
Where necessary, move the limit switches up or down (no more than
6mm at a time) to ensure the door fully opens and closes without excessive
slamming. Go through stages 1–4 each time a limit switch is adjusted.
15
6a Configuring the power and
sensitivity set up
Ensure that the power switch on the unit is in
the OFF position (see Figure 25).
NOTE:
Before commencing power set up
sequence ensure that:–
a
Limit switches are adjusted to their
nominal positions
b
All latches operate correctly
c
Drive pin is correctly engaged
d
Door is clear of obstructions
Plug in the power supply cable (Figure 25)
and turn on at the mains, but leave the switch
on the unit turned OFF for the moment.
1
Press and hold down the button.
Turn on the unit power switch then release
the button.
Power input
socket and
fuse
Bell push
connector
ON/OFF
switch
Lamp out
connector
•
Figure 25
CD PRO IMPORTANT NOTE:
When setting TOP limit on CD PRO ensure the
wheel spindle fully enters the SAFEHOLD on LH track.