![Captron Electronic safeCAP SC30 Operating Instructions Manual Download Page 16](http://html1.mh-extra.com/html/captron-electronic/safecap-sc30/safecap-sc30_operating-instructions-manual_2554873016.webp)
►
Disconnect safeCAP SC30 from the machine.
►
Connect a meter to the contacts of the safety relay that release the
machine function.
►
Actuate the SC30s one after another.
a
The LEDs must light up in green and yellow.
a
The safety relay must not release N/O or N/C contacts.
Switching on must be verified at the output contacts of the safety relay
using the meter and must not exceed the safety times (0.5 s in this case).
►
Disconnect the safeCAP SC30 from the power supply.
►
Actuate and continue actuating the SC30.
►
Restore the power supply.
a
The LEDs must light up in green and yellow.
a
The safety relay must not release N/O or N/C contacts.
6
Operation
6.1
Operating safeCAP SC30
►
Touch both safeCAP SC30 switches simultaneously (within 0.5 s).
►
The machine process is triggered.
6.2
Operating safety relay SCR3-3SK1
TIP
More detailed information can be found in the supplier documentation.
7
Maintenance
7.1
Maintenance operations
Carry out the following maintenance operations at the specified intervals.
16/25
1.1
safeCAP SC30
Original operating instructions