![Captron Electronic safeCAP SC30 Operating Instructions Manual Download Page 13](http://html1.mh-extra.com/html/captron-electronic/safecap-sc30/safecap-sc30_operating-instructions-manual_2554873013.webp)
5.7
Install safety relay PNOZ s6 (optional)
TIP
More detailed information can be found in the supplier documentation.
5.8
Connect safeCAP SC30 to safety relay PNOZ
s6
►
Disconnect the system from its voltage supply.
►
Connect safeCAP SC30 to the safety relay using a 6-pin M 12 cable
according to the circuit diagram. The optional cables LKW 60-5 (5 m) /
LKW 60-10 (10 m) or LKG 60-5 (5 m) / LKG-60-10 (10 m) can be used.
+VDC
0V
PhotoMOS-Relay NC
PhotoMOS-Relay NO
4
7
1
2
3
5
LED1
LED2
NO 24 V
NO
NC
NC
Y
+
S11
S12
S11
S22
S22
S21
S12
S21
A
B
-
0 V
24 V
+
-
0 V
safeCAP SC30
Original operating
instructions
1.1
13/25