background image

WF1544

Caple Free Standing wine cabinet

Technical information

Summary of Contents for WF1544

Page 1: ...WF1544 Caple Free Standing wine cabinet Technical information...

Page 2: ......

Page 3: ...board 1 19 DG13 247 Watertight shutter 1 20 DG19 6 Fan cover 2 21 DG22 250 Electrical box 1 22 DG13 32 1 Displayer holder 1 23 DG3 17 W LED light 1 24 DG13 130 S button 4 25 DG20 280 Display panel 1 2...

Page 4: ...170 SR Lower hinge module right 1 41 DG13 6 16 Cabinet leg type BC50 4 42 DG22 240 Support bracket of front legs 1 43 DG12 91 1 Condenser 1 44 DG14 170 SL Lower hinge module left 1 45 DG13 366 B Door...

Page 5: ......

Page 6: ...hows the reference page 6 Warning before attempting any cleaning or maintenance this unit MUST be disconnected from the electrical supply to prevent electrical shock Preparation before maintenance Equ...

Page 7: ...noise 7 Refrigerant jet noise 10 Capillary vibration noise 10 Oil jam noise 10 Evaporator freezing 11 The instability of the wine cellar temperature 11 Control system problems Fault finding by the se...

Page 8: ...6 Diagram show power PCB 17 How to remove power PCB board and the transformer 17 How to replace the switch 18 How to replace the Led light 19 Heating system problems How to evaluate the fault 20 How t...

Page 9: ...d in electrical box WF1104 character 1 1 Normal dual temperature wine cellar 5 10 for upper compartment 10 18 for lower compartment 5 12 for upper compartment 12 18 for lower compartment include 1 eva...

Page 10: ...it is possibly the refrigeration system leak The maintain procedure is following a Cut off discharge pipe from compressor and charge with refrigerant to 0 8 1Mpa nitrogen via the process pipe Then pla...

Page 11: ...f the low pressure pipe which on the process pipe of compressor 5 6 Fig 5 Fig 5 1 showing A the high pressure pipeline which on the process pipe of the drain filter Fig 5 Fig 5 1 showing G Apply the v...

Page 12: ...out Fig 1 1 3 Low rail installation As same as fixing block installation Fig 1 2 There are three kinds of air duct board 1 For normal dual temperature model a Remove the screw 1 of top middle air duc...

Page 13: ...connectors then take out air duct board E Fig 2 3 4 For single temperature model which the evaporator s fan and PTC heater s fan fitted at top of inner a Remove 5 screws 1 Fig 4 then take out the ele...

Page 14: ...n E Upper compartment s circulating pipe solder conjunction F Condenser solder conjunction G Dry filter seal pipe solder conjunction H Lower compartment s capillary solder conjunction I Connecting pip...

Page 15: ...tion rubber or adjust fixing screws Fan noise 1 When the fans are running the vanes are circumrotating rapidly and the air flows which will cause steady and standard noise The noise should not exceed...

Page 16: ...e out lower middle air duct board unplug fan s connector replace the fan Fig 6 3 4 How to replace condenser fan a Remove snap rings A take out compressor electrical s cover 9 Fig 7 b Mark relevant not...

Page 17: ...12 Fig 13...

Page 18: ...er reason below 1 The capillary being insert too deep into the evaporator so when the refrigerant is Jetting the end of vibrating capillary will hit the inside of the evaporator 2 Vibration from the c...

Page 19: ...the door See Fig 8 The instability of the wine cellar temperature The instability temperature is caused by evaporator s fan on off Solution When the compressor is on the indicator light on control pa...

Page 20: ...I it case as below a The capillary is jamed Please find the maintain procedure to Page 4 b The refrigerant value is fault please replace a new one 12 Fig 9 c The evaporator fan is fault please replace...

Page 21: ...er plough if not replace the sensor with the same module 7 Fig 6 b The LED display shows E2 and it is the upper compartment sensor s fault fault check the connection wire and the main board whether sh...

Page 22: ...Take our air duct board 7 Fig 6 Fig 6 1 3 Take out 2 screws 2 the sensor cover is loosed unplug sensor s connector on PCB board and take out the sensor replace a new one 7 Fig 6 2 Frost free unit s s...

Page 23: ...and vacuumize it and add refrigerant complete the replacement Fig 9 LED display fault This fault caused by led displayer just change it will be OK 13 Fig 10 Fig 10 1 How to replace the PCB board Here...

Page 24: ...ve the display board E and its two connectors from both sides Replace the display board See Fig 10 Vlew I 4 The way to replace synchronous dual temperature wine cellar s PCB board is as same as normal...

Page 25: ...of the lower zone sensor yellow X9 Connectors of the upper zone evaporator fan yellow X11 X12 Connectors of the lower zone display board X13 X14 Connectors of the upper zone display board X15 Connecto...

Page 26: ...onnectors of the LED light red if fix white lamp no this connector X16 Connectors of power PCB board This is drawing for power PCB board Fig 13 1 PTC heater connector White 2 Input terminal of the tra...

Page 27: ...emove the electrical box Fig 14 2 3 Unplug all the connecters then press the head of each of the four plastic screws 4 move up ward the control board A then replace a new one Fig 14 3 View K 4 Plug al...

Page 28: ...the connected line then change the same spec of switch Fig 15 2 The way to replace synchronous dual temperature wine cellar s waved switch is as same as normal dual temperature wine cellar s one 3 For...

Page 29: ...to replace normal dual temperature wine cellar s lower LED light Fig 17 1 Remove the shelves 4 Fig 1 Fig 1 1 2 Remove upper air duct board 5 Fig 2 1 3 Unplug connecter C press the head of each of the...

Page 30: ...room is lower than setting point the fan stop turning please check fan connecter if connecter is normal it is fan fan fault please replace a new one 7 Fig 6 2 Check PTC heater Check the cold resistanc...