Capetti Elettronica WSD12PS-4AI User Manual Download Page 10

WSD12PS-4AI 

User Manual

 

 

 

 

 

PAGE   10

 

 

WA0285E_WSD12PS-4AI_User Manual_R06 V6.0 

 

www.

capetti

.it 

14.

 

Product versions 

The device can be supplied in various versions, by the application. 

The following table shows different features and identify the related ordering code. 

 

Warm-Up 

Cable 
gland 

Valve 

CH1 

CH2 

CH3 

CH4 

 

Default 

Range 

PG 

Goretex 

WSD12PS-4AI 

1 second 

From 1 to 32 
seconds 

 

Proportional 

Proportional 

Proportional 

Proportional 

WSD12PS-4AIM4 

1 second 

From 1 to 32 
seconds 

 

Proportional 

Proportional 

Proportional 

Proportional 

WSD12PS-4AIM8 

1 second 

From 1 to 32 
seconds 

 

Temperature  

(

-30 

÷

 

+80°C

NTC3K 

Proportional 

Proportional 

Proportional 

WSD12PS-4AIM9 

12 seconds 

From 1 to 32 
seconds 

 

0

÷

25mA 

WSD12PS-4AIM10 

5 seconds 

From 1 to 32 
seconds 

 

0

÷

25mA 

0

÷

25mA 

0

÷

25mA 

0

÷

25mA 

Picture 11 - Product code nomenclature 

15.

 

Technical Information 

Power supply 

Double 5,8Ah - 

3,6 V type “C” lithium internal battery

 

Battery life (*) 

Up to 3 years  

(with 100mA charge distributed on 4 analog channels, 1 second 
warm-up time, 12V or 24V power supply, samples every  60 minutes 
and radio signal quality at least sufficient)

  

Power supply generated for transducers 

+12Vdc or +24Vdc (

up to 100mA

) - (

Selectable onboard using jumpers

Warm-up time 

From 1 (

default

) to 32 seconds (

Selectable using 

WineCapManager

) 

Sampling interval 

(*)

 

Selectable from one minute to 24 hours 

(

60 minutes default

)

 

Datalogger capacity 

64,000 samples (

for each channel

Working temperature 

 

Operative: -

30°C ÷ +60°C

 

 

Warehousing: -

40°C ÷ +70°C 

 

Radio frequency 

ISM 868MHz 

Radio coverage 

Up to 6Km in line of sight 

(

can be extended using WR12 battery powered repeaters

Sealing 

IP65 

Dimensions 

90x160x50mm 

Weight 

450g 

Case material 

ABS 

Mounting 

Fix on 4 points 

Connections 

Wireless, USB 

Cable external diameter 

4.7mm maximum 

Copper wire section 

0.05 ÷ 2.5mm² / ÷ 14 AWG

 

Measures acquired (

4 channels

Possible Input Signals (

up to 4

0÷5V

dc

, 0÷10V

dc, 

0÷25Vdc, 0÷25mA

 

Measures acquired (

4 channels

) - Resolution 

12 bits converter 

Measures acquired (

4 channels

) - Measurement Expression 

Expressed as full scale % setting 

Measures acquired (

4 channels

) - Transducers Connection 

Through 5mm pitch screw terminal blocks 

Measures acquired (

4 channels

Settings (

measure/system of measure

Using jumpers (***) 

* battery life may be influenced by fieldwork conditions, sampling/measuring interval and system configuration. 
** radio coverage can be extended using up to 32 WR12 repeaters (maximum 16 for each path) between the device and the basestation. 
*** refer to selected 

transducer’s documentation. Setup DIP switches in proper way.

 

 

Summary of Contents for WSD12PS-4AI

Page 1: ...WSD12PS 4AI User Manual ...

Page 2: ...p to 100mA distributed on 4 analog channels Measurements acquired are expressed in percentage of full scale 2 Channel description Picture 1 Product image SHIELD shield cable connection PS INPUT datalogger generated voltage negative pole Input signal negative reference INPUT Signal input 0 25mA 0 5Vdc 0 10Vdc 0 25Vdc Full scale selectable using scale jumpers PS datalogger generated voltage positive...

Page 3: ...c 100mA default Picture 3 Jumper positions Removing jumper J10 Errore L origine riferimento non è stata trovata voltage generation on pin PS of the terminal block is disabled This situation may be useful in case the DC voltage is not necessary Consequently the battery life is increased 4 Full scale setting The measurement s full scale selection is done positioning a jumper on the proper strip 0 25...

Page 4: ...PS 4AI can be programmed using WineCapManager to supply a warm up time variable from 1 default to 32 seconds Be sure that the device is linked to its gateway refer to 10 Installation procedure Run WineCapManager and open the plant related database If the database doesn t exist and the gateway is not properly licensed on connected PC refer to WineCap System User Manual R30 From the WineCapManager m...

Page 5: ...ww capetti it Click on InfoReq button Select the card Calibration Modify the Zero field with the desired warm up value default 1 maximum 32 The inserted value is expressed in seconds and represents the duration of output power supplied to transducer net off 0 4s of tolerance ...

Page 6: ...ociate it make reference to the WineCap System User Manual R30 software manual It is necessary to use the WineCapManager software on the PC connected to the gateway that will be linked with the device b USB Logger Mode For this operation mode stand alone with data downloads through USB the connection with the PC and the WineCapManager running on it is necessary to modify the device s operation mod...

Page 7: ...flashes STANDBY Temporary device deactivation the device is stopped The sampling process and the radio are is turned off losing the connection to the network To reactivate a TEST command is necessary The STANDBY command must be given twice to confirm it at the first sequence the led flashes alternating RED and GREEN lights waiting for the second confirm sequence within 15 seconds At the command ex...

Page 8: ...TUS RADIO SIGNAL QUALITY 5 green flashes ACTIVE Radio signal Excellent 4 green flashes ACTIVE Radio signal Good 3 green flashes ACTIVE Radio signal Fair 2 amber flashes ACTIVE Radio signal Sufficient 1 red flash ACTIVE Radio signal Insufficient 1 red flash 2 long OUT OF RANGE Network searching 2 red flashes 2 long STANDBY Radio off No Logging Short long short red flashes series FACTORY RESET Devic...

Page 9: ...time you can issue the STANDBY command refer to Picture 7 Command table It corresponds to the command number 4 and must be issued twice to confirm the operation Position the WineCapKey in the spot indicated in Picture 6 WineCapKey positioning and wait for four AMBER flashes then remove the WineCapKey from device Verify that the device asks for confirmation of STANDBY command with alternate GREEN R...

Page 10: ... up to 100mA Selectable onboard using jumpers Warm up time From 1 default to 32 seconds Selectable using WineCapManager Sampling interval Selectable from one minute to 24 hours 60 minutes default Datalogger capacity 64 000 samples for each channel Working temperature Operative 30 C 60 C Warehousing 40 C 70 C Radio frequency ISM 868MHz Radio coverage Up to 6Km in line of sight can be extended using...

Page 11: ...ion voltage measures on distances exceed 15 20 meters are subjected to electromagnetic disturbances 0 25mA inputs have a superior electromagnetic compatibility EMC Avoid passage in cavities with power or high voltage cables The protection and safety measures and the warranty provided by the Manufacturer with the equipment may be compromised if it s used in a manner that does not comply with this u...

Page 12: ...nic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point The end user should contact the device provider either the manufacturer or the...

Reviews: