CAUTION!
•
Never touch electrical connections with wet or damp hands. This could result in an electric shock.
•
Never use the unit for any purpose other than that for which it is intended.
•
Do not step on the indoor unit.
•
Do not place objects above the indoor unit.
•
Never expose people, pets or pot plants to cold draughts.
•
Do not use insecticides or flammable gases on the unit; this could cause a fire or result in the deformation of the unit.
•
Never place burning objects in proximity to the unit.
•
Never support the unit on a damaged or rusty stand.
•
Never install the unit in close proximity to highly flammable gases; this could cause a fire or explosion.
•
Switch off the power to the unit if it will not be used for an extended period.
•
Shut down the unit and switch off the power to the unit during thunder storms etc. Otherwise electrical components may be damaged.
•
Ensure that the drain hose is correctly connected; otherwise water could leak out and cause damage.
•
Ensure that condensate can run out unimpeded, otherwise water damage could occur.
•
The electrical connection to the unit must be earthed.
•
For your safety we recommend that you install a residual current device.
COMPONENTS
Indoor unit:
1. Front panel
2. Air intake
3. Air filter
4. Air vent
5. Horizontal air deflector
6. Vertical air deflector
7. Information display (LED)
Outdoor unit:
8. Refrigerant pipe/connection
9. Connection cable
10. Service ports
NOTE!
Illustrations in this manual are only descriptive; the actual
appearance of components may vary.
THE INDOOR UNIT INFORMATION DISPLAY
Turbo- Shows when this function has been activated.
Defrost- Lights when the unit starts defrosting automatically or
when there is a heated air flow in heating mode.
Run- Lights when the unit is running.
Timer- Lights when this function is running.
The temperature indicator on the front panel.
•
Displays the temperature setting/function when the unit is
running.
•
Displays any fault codes.
Model
Indoor unit – model designation
QHW-S*09*
QHW-S*12*
Outdoor unit – model designation QHX-S*09*
QHX-S*12*
Indoor unit – dimensions
WxDxH (mm)
835x198x280
835x198x280
Outdoor unit – dimensions
WxDxH (mm)
810x310x558 (QHX-S*09
A
)
800x333x554 (QHX-S*09
B
)
810x310x558 (QHX-S*12
A
)
800x333x554 (QHX-S*12
B
)
Refrigerant type
R410A
R410A
Power supply
~ /N, 230 V, 50 Hz
~ /N, 230 V, 50 Hz
4
3
5
2
6
1
9
10
8
7
INDOOR UNIT
OUTDOOR UNIT
DISPLAY & FUNCTION LAMPS
turbo defros t run
timer
SPECIFICATIONS
(* in the model designation = different variants/versions of the model)
turbo defrost run
timer
EN
EN