CANTERBURY Z3450 Installation Instructions Manual Download Page 1

   

 

 

 

 

 

 

 

 

 

 

 

Adore sink mixer pivoting tube 

Art:  Z3450 

 

• Handmade in Italy since 1960 
• ¼ Turn valves handmade at 

Nicolazzi Factory 

• Lead Free Brass Compliant to 

AZ/NZS 3718 

• Suitable even and uneven 

pressure 

• Handles are interchangeable 
 

Specifications 

WM22315 

AS/NZS3662 
Canterbury Sink & Tap Co. 

Max/Min Operating 
Pressure: 100/500kPa 

Further information Phone (03) 9761 4603                               [email protected] 

 

 

 

 

 

Summary of Contents for Z3450

Page 1: ...made at Nicolazzi Factory Lead Free Brass Compliant to AZ NZS 3718 Suitable even and uneven pressure Handles are interchangeable Specifications WM22315 AS NZS3662 Canterbury Sink Tap Co Max Min Operat...

Page 2: ...m Please note The recommended pressure for best performance is between 270 kPa and 420 kPa More pressure than 420 kPa or less pressure than 270 kPa may affect the diverting action in side spray tap wa...

Page 3: ...hoses 2 into the tap body 1 Note Hand tighten only DO NOT over tighten 2 Install the water supply hoses 3 into the tap body 1 Note Hand tighten only DO NOT over tighten 3 3 Preparation Flush out the...

Page 4: ...he mounting surface is irregular the nut may not be secured and the tap will be loose on the sink Installation Instructions Model Z3450 Further information Phone 03 9761 4603 sales sinkandtap com au F...

Page 5: ...5 Before use Turn on the Hot and Cold supplies to the tap Maximum temperature for Hot water supply to the tapware is 62 C Minimum recommended pressure is 100 kPa Maximum recommended pressure is 500 k...

Page 6: ...Spare Parts list Model Z3450 Further information Phone 03 9761 4603 sales sinkandtap com au 6...

Page 7: ...The retaining flange only needs to be hand tight NOTE DO NOT USE A SHIFTER TIGHTEN BY HAND ONLY Do not over tighten as this could damage the ceramic cartridge Removing and replacing a handle MODEL SHO...

Page 8: ...es to the tap Not shown Remove handle as per Removing Replacing handle directions Remove the cartridge nut with a 27mm socket set or shifter Once the cartridge nut is loose simply remove the cartridge...

Page 9: ...ncing low flow from the spout Do not change the cartridge Unscrew and clean the aerator 1 Unscrew and clean the filters inside the supply connections 2 Check the supply lines for kinks or obstructions...

Page 10: ...juice this will lighten the dark colouring Shiny Brass Polished Nickel has an ageing process and will tarnish over time Tuscan Brass is a living finish and also carries NO warranty It will lighten wi...