background image

 
Webster 64 Controller  

INSTALLATION MANUAL 

 

  

 

 

 

September 2023

 

 

Summary of Contents for Webster 64

Page 1: ...Webster 64 Controller INSTALLATION MANUAL September 2023...

Page 2: ...12 Lock Output and Multi Function Relay Wiring 15 Appendix 17 WEBSTER 64 System Indicators 18 Power Connector 19 PB1 Shutdown Button 20 PB2 IP Reset Button and Static IP Address Configuration 20 USB I...

Page 3: ...4 doors from the factory However additional controllers like MAPmini MAP1 and MAP2 controllers can be added and governed by the Webster 64 controller to increase the number of door capacity The Webste...

Page 4: ...l Relays 8 per panel Form C SPDT 6 A 30 VDC Inputs per Provisioned Doors Supervised or Non Supervised Door Contact 2 per Webster 64 Requires normally closed contact On Off door switch Exit Button 2 pe...

Page 5: ...Webster 64 Page 5 of 32 Installation Manual February 2024 Rev 1 1 Note Specifications subject to change without notice...

Page 6: ...gency lockdown functions which are dependant in any way on the operation of card readers access control panels communications networks communications devices or host software Wiring Note Improper Wieg...

Page 7: ...Webster 64 Page 7 of 32 Installation Manual February 2024 Rev 1 1 Webster 64 Controller Layout Figure 1...

Page 8: ...capacity can be increased to a maximum of 64 doors These additional controllers must be provisioned in First Access mode Management is done through the Webster 64 controller Electrical Information 1 T...

Page 9: ...f access is to be limited to the external connections 3 If a Lockable external enclosure is used and a Tamper switch is available as in the CA SLBOX or CA H1000ENCL the Webster 64 has a Panel Tamper i...

Page 10: ...ate power supply battery backed up just for the Webster 64 Controller and a separate power supply which can be sized to supply the amount of current that the attached high current devices locks will r...

Page 11: ...agram shows entry reader wiring only For entry and optional exit reader wiring diagram proceed to the next section READER LED ON Reader Active Two Inputs and two Outputs are used for RTE REX door cont...

Page 12: ...the MSJx position See figure 6 below Reader 1 uses Input 1 Door Contact DPS and Input 2 RTE REX Reader 2 uses Input 3 Door Contact DPS and Input 4 RTE REX Reader 3 uses Input 5 Door Contact DPS and In...

Page 13: ...Webster 64 Page 13 of 32 Installation Manual February 2024 Rev 1 1 Figure 6 Non Supervised...

Page 14: ...Webster 64 Page 14 of 32 Installation Manual February 2024 Rev 1 1 Figure 7 Supervised...

Page 15: ...f the following options Alarm Shunt factory default Shunt the alarm system before opening lock Door Held Open DHO Door is left open Forced Entry Door opened without access granted or exit button press...

Page 16: ...urisdiction to verify the specific requirements Also a building permit may be required in some jurisdictions for the installation of magnetic locks Figure 9 See Note 2 in Appendix section for 6 Amp re...

Page 17: ...atteries 13 5 x 13 x 3 25 342 9mm x 330 2mm x 82 6mm 7 2 lb 3 27 kg 12 24 VDC selectable output 12VDC 4A or 24VDC 3A supply current Eight 8 Class 2 Rated PTC protected power limited outputs auto reset...

Page 18: ...dicates 12 volts DC is connected MEBR LED MEBT LED For future use Webster Mode Mode indicator Webster 64 emits 2 beeps after powered up PM1 LED ON PM2 LED OFF IOM LED Flashing RED IOM Input Output Mod...

Page 19: ...ected to METTAM TAMPER allows for the connection of an external Enclosure Tamper Switch Note The Webster 64 has a Tamper MSJx MicroShunt jumper to the right of this power connector Figure 13 Factory d...

Page 20: ...s will take 15 to 20 seconds 3 Wait untill all LEDs except power are turned off by the system Then remove the Power Connector 4 If the Shutdown does not occur try the procedure again If it still does...

Page 21: ...t 3 beeps 3 Plug the Webster 64 to the network with a DHCP server available 4 Install and launch IP Configuration Tool from your computer This tool is available from the First Access software installa...

Page 22: ...elect Enable DHCP Consult with IT personnel and enter the IP address Subnet Mask Gateway IP Address and Port numbers Note The optional Trusted Host IP see Figure 18 instructs the panel to accept data...

Page 23: ...d reboots for the settings to take effect USB IP CONFIGURATION TOOL Important Shutdown Push Button PB1 must be used to avoid data corruption on the Webster 64 controller 1 If the Webster 64 controller...

Page 24: ...r 64 controller The unit will begin the power up sequence which takes about 30 to 40 seconds When complete the Webster 64 controller will emit 3 beeps 6 Remove the USB flash drive from the Webster 64...

Page 25: ...ry default update port Encryption 0 For future use only Authenticate 0 For future use only IpSecurity 0 Specify if trusted host is enabled or disabled 1 enabled 0 disabled ClientIp 0 0 0 0 If IpSecuri...

Page 26: ...ive into a USB port on a computer When ready launch Windows Explorer or File Explorer Access the USB drive and check if there is an error file present along with the file 12 If no error file is presen...

Page 27: ...2 Press and hold the IP RESET PB2 button 3 After approximately 3 5 seconds the Webster 64 controller will emit a continuous beep Release the IP RESET PB2 button 4 The Webster 64 controller will be re...

Page 28: ...uary 2024 Rev 1 1 8 Under Advanced network settings select Change adapter options 9 Right click on your network adapter in this example it s Ethernet 2 and select Properties 10 Select Internet Protoco...

Page 29: ...and select User configured then enter the IP address of 10 0 0 200 followed by the Subnet mask of 255 255 255 0 When done select OK all the way out 12 Your network card is now configured with an alte...

Page 30: ...MF multifunction relay when configured as Forced Entry will be activated if the door is forced open without either an access granted or an exit button event A message will be recorded and displayed i...

Page 31: ...on relay when configured as Door Operator All Cards will be activated by all cards and by exit button press The lock relay will be activated first followed by a one second pulse on this MF relay which...

Page 32: ...Webster 64 Page 32 of 32 Installation Manual February 2024 Rev 1 1...

Reviews: