Setting of Numeric Parameter (NUMERIC Param.)
Configuration of Numeric Parameters
<1/10>
<READY>
Report
Sssw Menu
Num
Ncu Type IPFAX Print Clear Test
OK
001
002
003
004
005
006
007
008
xxxxx
xxxxx
xxxxx
xxxxx
xxxxx
xxxxx
xxxxx
xxxxx
←
㸦
yyyyy
㸧
{aaaaa
㹼
bbbbb}
←
㸦
yyyyy
㸧
{aaaaa
㹼
bbbbb}
←
㸦
yyyyy
㸧
{aaaaa
㹼
bbbbb}
←
㸦
yyyyy
㸧
{aaaaa
㹼
bbbbb}
←
㸦
yyyyy
㸧
{aaaaa
㹼
bbbbb}
←
㸦
yyyyy
㸧
{aaaaa
㹼
bbbbb}
←
㸦
yyyyy
㸧
{aaaaa
㹼
bbbbb}
←
㸦
yyyyy
㸧
{aaaaa
㹼
bbbbb}
No.
Function
Setting range
Default value
002
RTN transmission condition (1)
1 to 99%
10
003
RTN transmission condition (2)
2 to 99 times
15
004
RTN transmission condition (3)
1 to 99 lines
12
005
NCC pause time (before ID code)
1 to 60 sec
4
006
NCC pause time (after ID code)
1 to 60 sec
4
007
Prepose time at the time of making a call
0 to 9999 (x 10 ms)
0
009
Comparing the number of digits between the sender's telephone number
and the receiver's telephone number
0 to 20 digits
0
010
Line connection identification time
0 to 9999 (x 10 ms)
5500
011
T.30 T1 timer (for reception)
0 to 9999 (x 10 ms)
3500
013
T.30 EOL timer
500 to 3000 (x 10 ms)
1300
015
Hooking detection time
0 to 999
120
016
Time until a temporary response is obtained when switching FAX/TEL
0 to 9
4
017
Pseudo RBT signal pattern ON time
0 to 999
100
018
Pseudo RBT signal pattern OFF time (short)
0 to 999
0
019
Pseudo RBT signal pattern OFF time (long)
0 to 999
200
020
Pseudo CI signal pattern ON time
0 to 999
100
021
Pseudo CI signal pattern OFF time (short)
0 to 999
0
022
Pseudo CI signal pattern OFF time (long)
0 to 999
200
023
CNG detection level when switching FAX/TEL
0 to 7
4
024
Pseudo RBT transmission level when switching FAX/TEL
10 to 20 (TYPE =
STANDARD)
20
025
CNG monitoring time when the answering phone connection function is
set
026
Silent detection level when the answering phone connection function is
set
027
V.21 low-speed flag preamble detection time
20 (-10 ms)
0
028
Off-hook PCB duty settings
1 to 99%
0 (50%)
080
Transmission number restriction: Outside line transmission number *1
0 to 9999
0
*1 : Supported on the platform version 307 or later
002: RTN transmission condition (1)/003: RTN transmission condition (2)/004: RTN transmission
condition (3)
Set the RTN signal transmission condition.
5. Service Mode
35