CHAPTER 2 OPERATIONS AND TIMING
2-50
COPYRIGHT © 1998 CANON INC.
CANON STAPLER SOTRER-L1 MS-C1 REV.0 NOV. 1998 PRINTED IN JAPAN (IMPRIME AU JAPON)
VI. POWER SUPPLY
Figure 2-601 shows how power is distributed.
The machine is supplied with 24V power through two systems.
24 VP is supplied to the stapler unit swing motor, feed motor, and guide bar swing motor by
way of a circuit breaker.
24 VPA is turned into 24 VPB through a joint, and is supplied to the stapler unit home position
switch.
24 VPB, on the other hand, is turned into 24 VPC through the stapler unit home position
switch, and is supplied to the load detecting switch and the bin shift motor.
The bin shift motor is supplied not only with 24 VPC (for ascent) but also with 24 VPD (for
descent) through a load detecting switch.
The stapler motor is supplied with 24 VPE coming through the stapler door switch.
24 VL is converted by the regulator circuit on the sorter controller PCB into 5 V for supply to
the logic system and the various sensors.
Copier
Sorter controller circuitPCB
Circuit breaker
Joint
Regulator
circuit
Logic
system
Sensor
system
Stapler unit sswing motor *1
Feed motor
Guide bar swing motor *1
Stapler cover
switch *1
Stapler motor *1
Bin shift motor
Stapler unit home
position switch *1
Load detecting
switch
24VPD
24VPC
24VPE
24VPB
24VPA
24VP
24VL
5V
SW1
SW2
SW3
CB1
M1
M2
M3
M5
M4
*1 Stapler sorter only.
Figure 2-601