Chapter 3
3-3
3.2.4
E591
0003-8764
T-3-6
Code
Detail
Error
Description
Detection timing
E591
8001
Scrap full
detector sensor
(LED6,PTR6)
The voltage of the light received is 3.0 V or
less even when the light emitting duty of the
scrap full detector sensor has been increased
to 66% or more.
8002
The voltage of the light received is 2.0 V or
more even when the light emitting duty of the
scrap full detector sensor has been decreased
to 0%.