Chapter 2: Service Error Codes
2-6
Cause
Remedy
##011
[ RX ] In G2 reception, the image signal cannot be
received for 5 sec after transmission of
CFR2
• Ask the operator of the other party to in-
crease the transmission level
*1
so that the
image signal may be received correctly.
• Adjust the NL equalizer
*2
so that the im-
age signal may be received correctly.
• The line condition is poor, and the image
signal cannot be received correctly.
Cause
Remedy
##012
[ RX ] In G2 reception, a signal other than PIS or
GC2 is received after transmission of MCF2
or GI2
• Record the protocol on a DAT or MD, and
have it analyzed by the local Canon office
and/or Technical Center.
• The procedure signal has a fault.