Chapter 2: Service Error Codes
2-147
Cause
Remedy
##1034 [ TX/RX ] No circuit/channel available
[ TX/RX ] No access to a closed user group
[German model]
• The other party is busy. Wait a while, and
start a communication once again.
• Print out a communications analysis list,
and analyze it.
• Contact the telephone company or the ex-
change manufacturer to find out the nature
of cause number #34.
• Start a communication once again.
• Print out a communications analysis list,
and analyze it.
• Contact the telephone company or the ex-
change manufacturer to find out the nature
of cause number #34.
• Cause number #34 (No circuit/channel
available) arrived from network.
• Cause number #34 (No access to a closed
user group) arrived from network.
Cause
Remedy
##1035 [ TX/RX ] Closed user group not exist
[German model]
• Check the other party, and start a commu-
nication once again.
• Print out a communications analysis list,
and analyze it.
• Contact the telephone company or the ex-
change manufacturer to find out the nature
of cause number #35.
• Cause number #35 (Closed user group not
exist) arrived from the network.
Summary of Contents for PowerShot G3
Page 12: ...Introduction X This page intentionally left blank ...
Page 13: ...Chapter 1 User Error Codes ...
Page 58: ...Chapter1 User Error Codes 1 45 Cause Remedy Cause Remedy ...
Page 59: ...Chapter1 User Error Codes 1 46 Cause Remedy Cause Remedy ...
Page 60: ...Chapter 2 Service Error Codes ...
Page 275: ...Chapter 2 Service Error Codes 2 215 Cause Remedy Cause Remedy ...
Page 276: ...Chapter 2 Service Error Codes 2 216 Cause Remedy Cause Remedy ...
Page 277: ...Appendix ...
Page 310: ...0901 AT CANON INC ...