Chapter 2: Service Error Codes
2-125
Cause
Remedy
##786
[
TX
] In ECM transmission, a signal other than
ERR was received after transmission of
EOR-EOP
• Record the protocol on a DAT or MD, and
have it analyzed by the local Canon office
and/or Technical Center.
• The procedure signal is faulty.
Cause
Remedy
##787
[
TX
] In ECM transmission, DCN was received
after transmission of EOR-EOP
• Increase the transmission level
*1
so that the
other party may receive EOR-EOP cor-
rectly.
• Adjust the NL equalizer
*2
so that the other
party may receive EOR-EOP correctly.
• Add an echo protect tone to the V.29 mo-
dem signal for transmission
*8
.
• Transmit once again.
• The line condition is poor, and the other
party cannot receive EOR-EOP correctly.
• The Stop key was pressed during a com-
munication.