Chapter 2: Service Error Codes
2-101
Cause
Remedy
##719
[
TX
] In CHT transmission, the block number did
not match in relation to the other party
• Record the protocol on a DAT or MD, and
have it analyzed by the local Canon office
and/or Technical Center.
• The procedure signal (the nature of REJ
from the other party) is faulty.
Cause
Remedy
##730
[ RX ] In CHT reception, the signal in response to
RR after transmission of an image signal
was not received for 6 sec, causing a time-
over condition
• Increase the transmission level
*1
so that the
other party may receive RR correctly.
• Ask the operator of the other party to in-
crease the transmission level
*1
so that the
signal may be received correctly.
• The line condition is poor, and the other
party cannot receive RR correctly.
• The line condition is poor, and the signal
in response to RR cannot be received cor-
rectly.