Chapter 2: Service Error Codes
2-53
Cause
Remedy
##300
[
TX
] Interface error occurred between the
reader and the controller
• Correct it by referring to the Service
Manual of the model in question.
• An internal unit is faulty (i.e., after the fluo-
rescent lamp goes ON, the WAIT signal
does not go OFF for 8 sec while in wait
for a response from the reading block).
Cause
Remedy
##301
[
TX
] Interface error occurred between the
reader and the controller
• Correct it by referring to the Service
Manual of the model in question.
• An internal unit is faulty (i.e., after pre-
scanning, the WAIT signal does not go OFF
for 3 sec while in wait for a response from
the reading unit).