Océ VarioPrint 135/120/110 Service Guide
Océ VarioPrint 135/120/110 Service Guide
January 2013
Revision 3
Page 49
Table 34 – Special Tools, Solvents, and Oils List - Continued
Tool
Part Number
Remarks
Test Chart 26a
Adjustment Image Reader
Open-end Spanner 4x5
Installation Attention Light
Open-end spanner 12x13
Height Adjustment Wheels
Gloves heat protected
Anti static wrist strap
Anti static service kit
Handling drum unit outside Engine
Ruler 300x13x0.5mm
Height Adjustment Wheels
Cutter
PFM Trays
Compressed air
Cleaning HOD Unit
Cloth Cleaning
Cleaner K
isopropyl alcohol
Cleaner T
Gloves Latex
Brasso
Cleaning Drum
Mouth Cap
Cleaning Drum
USB Flash Drive
V. Soft Counter
The VarioPrint 135/120/110 series uses soft counters to track its functional
copy use. The operator panel can display up to six (6) counters in the
Maintenance Mode (when the Maintenance button on the operator panel is
pressed). The VarioPrint 135/120/110 series operator panel displays up to six
(6) counters on the Maintenance Mode screen.
The Maintenance Mode screen shows two types of counters: Billing counters
and Day counters. Billing counters represent the total number of prints that
have been made since the machine was installed. The Day counters displays
the same counters, however, the day counters can be reset to zero (0). The
Day counters can be reset at any time (i.e., between jobs, daily or between
meter readings).
The table below indicates the default counter configurations of the VarioPrint
135/120/110 series in maintenance mode. Refer to the Technical Service
Manual for complete details on the Soft Counter configurations.
Table 35 – Soft Counter
Counter
Meter
Number
Counter Description
(from Service Manual)
Default
Display
Adjustability of Display
1
101
Total 1
On
May not be changed
2
102
Total 2 (large)
On
May be Changed via Service
Mode setting to any
available counter
3
103
Total (large)
On
4
104
Total (small)
On
5
112
Total (Black/Large)
On
6
113
Total (Black/Small)
On
Refer to the VarioPrint 135/120/110 Technical Service Manual for complete