■ After replacing CIS units
1. AGC adjustment
1. Entering a provisional value
Change the foregoing values to "1,000".
• COPIER > ADJUST > CCD > LED-BW-R
(Adjustment of LED light-up time (R) at B&W
reading)
• COPIER > ADJUST > CCD > LED-BW-G
(Adjustment of LED light-up time (G) at B&W
reading)
• COPIER > ADJUST > CCD > LED-BW-B
(Adjustment of LED light-up time (B) at B&W
reading)
Change the foregoing values to "1,200"
• COPIER > ADJUST > CCD > LED-CL-R
(Adjustment of LED light-up time (R) at color
reading)
• COPIER > ADJUST > CCD > LED-CL-G
(Adjustment of LED light-up time (G) at color
reading)
• COPIER > ADJUST > CCD > LED-CL-B
(Adjustment of LED light-up time (B) at color
reading)
2. Adjust the white level in the following service mode.
• COPIER > FUNCTION > CCD > BW-AGC
(CIS intensity adjustment in ADF (B&W))
• COPIER > FUNCTION > CCD > CL-AGC (CIS
intensity adjustment in ADF (color))
3. If the operation was "successful", this procedure is
completed. (There is no need to write the value on
the service label.)
4. How to judge whether the operation was successful
or failed
Whether the operation was successful or failed is
not shown on the UI, so perform the following
procedure to judge if the operation was successful
or failed.
B&W mode
• COPIER > ADJUST > CCD > LED-BW-R
(Adjustment of LED light-up time (R) at B&W
reading)
• COPIER > ADJUST > CCD > LED-BW-G
(Adjustment of LED light-up time (G) at B&W
reading)
• COPIER > ADJUST > CCD > LED-BW-B
(Adjustment of LED light-up time (B) at B&W
reading)
Check the foregoing values. If all of them remain
"1,000", the operation result is judged to be "failed".
If the operation result is judged to be "failed", turn
OFF and then ON the power, and execute COPIER
> FUNCTION > CCD > BW-AGC again.
Color mode
• COPIER > ADJUST > CCD > LED-CL-R
(Adjustment of LED light-up time (R) at color
reading)
• COPIER > ADJUST > CCD > LED-CL-G
(Adjustment of LED light-up time (G) at color
reading)
• COPIER > ADJUST > CCD > LED-CL-B
(Adjustment of LED light-up time (B) at color
reading)
Check the foregoing values. If all of them remain
"1,200", the operation result is judged to be "failed".
If the operation result is judged to be "failed", turn
OFF and then ON the power, and execute COPIER
> FUNCTION > CCD > CL-AGC again.
2. Automatic adjustment of the stream reading
position
1. Entering a provisional value
Set the value of
• COPIER > ADJUST > ADJ-XY > STRD-POS
(Adjustment of reading position at ADF stream
reading)
to "-20".
2. Automatic adjustment of the stream reading
position
Execute
• COPIER > FUNCTION > INSTALL > STRD-
POS (Scan position auto adj in ADF mode)
If the operation was successful, write the value of
STRD-POS on the service label.
4. Disassembly/Assembly
149
Summary of Contents for MF720 Series
Page 1: ...Revision 2 0 MF720 Series Service Manual...
Page 12: ...Product Overview 1 Product Lineups 5 Product Features 7 Specifications 8 Name of Parts 14...
Page 79: ...4 Click Import Export Import 1 2 2 Technical Explanation 71...
Page 103: ...Durable Parts No durable parts is set for this product 3 Periodical Service 95...
Page 104: ...Periodical Services No periodical service is set for this product 3 Periodical Service 96...
Page 232: ...Adjustment 5 Overview 225 Adjustment at Parts Replacement 226...
Page 248: ...Troubleshooting 6 Test Print 241 Trouble shooting items 243 Version Upgrade 244 Debug Log 248...
Page 258: ...Error Jam Alarm 7 Outline 251 Error Codes 252 Jam Code 257...
Page 267: ...Service Mode 8 Overview 260 COPIER 264 FEEDER 300 FAX 302 TESTMODE 308...
Page 322: ...APPENDICES Service Tools 315 General Circuit Diagram 316 Print Sequence 317 Backup Data 318...