Chapter 16
16-130
xx25
There is a fault/open circuit in the
SALT sensor.
The ITB has deteriorated.
The fault can occur as when a new drum
unit has been fitted. It is detected during
ATR control or in about 150 sec after
idle rotation of the developing
assembly.
xx30
There is a fault/open circuit in the
ATR sensor. The setting of the ATR
sensor computation value is wrong.
The drum unit is not fitted properly, or
is faulty.
The fault can occur as when a new drum
unit has been fitted. It is detected in
about 90 to 120 sec after idle rotation of
the developing assembly.
xx34
The sample image fails to be drawn in
ATR control. There is a fault/open
circuit in the SALT sensor. The drum
unit is faulty. The ITB has
deteriorated.
The fault can occur as when a new drum
unit has been fitted. It is detected during
ATR control or in about 150 sec after
idle rotation of the developing
assembly.
xx35
There is a fault/open circuit in the
SALT sensor.
The fault can occur as when a new drum
unit has been fitted. It is detached
during ATR control or in about 150 sec
after idle rotation of the developing
assembly.
xx40
The ATR sensor communication
value is faulty. There is a fault/open
circuit in the ATR sensor. The drum
unit has been fitted improperly. (The
machine cannot detect the drum unit).
The drum unit is faulty.
The fault can occur as when a new drum
unit has been fitted. It is detected in
about 90 to 120 sec after idle rotation of
the developing assembly.
xx50
The developer concentration
computation value is faulty (set when
a new drum unit is fitted).
The fault occurs when an image is
being formed. It is detected when toner
supply operation is started.
xx60
The developer concentration target
value is faulty (set when a new drum is
fitted; the value is extremely small).
The fault occurs when an image is
being formed. It is detected when toner
supply operation is started.
xx70
The developer concentration target
value is faulty (set when a new drum
unit is fitted; the value is extremely
small).
The fault occurs when an image is
being formed. It is detected when toner
supply operation is started.
xx80
The actual value is considerably high
in relation to the ITB surface
reflectance when a new drum unit is
fitted. The SALT sensor is faulty.
The fault occurs while ATR control is
being executed.
Detail
Description
Timing of detection
Summary of Contents for iR C3200 Series
Page 1: ...Dec 3 2004 Service Manual iR C3200 Series iR C3220N PRT ...
Page 2: ......
Page 6: ......
Page 40: ...Contents ...
Page 41: ...Chapter 1 Introduction ...
Page 42: ......
Page 44: ......
Page 73: ...Chapter 2 Installation ...
Page 74: ......
Page 144: ...Chapter 2 2 68 ...
Page 145: ...Chapter 3 Basic Operation ...
Page 146: ......
Page 148: ......
Page 158: ...Chapter 3 3 10 ...
Page 159: ...Chapter 4 Basic Operations As a Printer ...
Page 160: ......
Page 162: ......
Page 171: ...Chapter 5 Main Controller ...
Page 172: ......
Page 212: ...Chapter 5 5 38 ...
Page 213: ...Chapter 6 Original Exposure System ...
Page 214: ......
Page 250: ...Chapter 6 6 34 ...
Page 251: ...Chapter 7 Image Processing System ...
Page 252: ......
Page 254: ......
Page 260: ...Chapter 7 7 6 ...
Page 261: ...Chapter 8 Laser Exposure ...
Page 262: ......
Page 264: ......
Page 285: ...Chapter 9 Image Formation ...
Page 286: ......
Page 291: ...Contents ...
Page 292: ......
Page 396: ...Chapter 9 9 104 ...
Page 397: ...Chapter 10 Pickup Feeding System ...
Page 398: ......
Page 406: ...Contents ...
Page 437: ...Chapter 10 10 31 9 1 2 3 10 1 2 3 ...
Page 574: ...Chapter 10 10 168 ...
Page 575: ...Chapter 11 Fixing System ...
Page 576: ......
Page 580: ......
Page 650: ...Chapter 11 11 70 ...
Page 651: ...Chapter 12 Externals and Controls ...
Page 652: ......
Page 658: ...Contents ...
Page 729: ...Chapter 13 MEAP ...
Page 730: ......
Page 732: ......
Page 737: ...Chapter 14 Maintenance and Inspection ...
Page 738: ......
Page 740: ......
Page 749: ...Chapter 15 Standards and Adjustments ...
Page 750: ......
Page 752: ......
Page 766: ...Chapter 15 15 14 ...
Page 767: ...Chapter 16 Correcting Faulty Images ...
Page 768: ......
Page 785: ...Chapter 16 16 11 6 Mottled Image F 16 12 7 Flow image on Side F 16 13 8 Toner Stray F 16 14 ...
Page 789: ...Chapter 16 16 15 2 20 to 30 mm White Spot F 16 23 3 White Spots Leading Edge F 16 24 ...
Page 826: ...Chapter 16 16 52 F 16 45 ...
Page 835: ...Chapter 16 16 61 Image1 F 16 50 Image2 F 16 51 ...
Page 977: ...Chapter 17 Self Diagnosis ...
Page 978: ......
Page 979: ...Contents Contents 17 1 Error Code Details 17 1 17 1 1 Error Code Details Table 17 1 ...
Page 980: ......
Page 1002: ...Chapter 17 17 22 ...
Page 1003: ...Chapter 18 Service Mode ...
Page 1004: ......
Page 1128: ...Chapter 18 18 122 ...
Page 1129: ...Chapter 19 Upgrading ...
Page 1130: ......
Page 1132: ......
Page 1141: ...Chapter 19 19 9 5 Click Register Firmware F 19 8 6 Click Register from selected folder F 19 9 ...
Page 1156: ...Chapter 19 19 24 T 19 5 F 19 32 T 19 6 Normal Mode Safe Mode ...
Page 1185: ...Chapter 19 19 53 2 Select DCON and click Connect F 19 73 3 Click Set host name F 19 74 ...
Page 1192: ...Chapter 19 19 60 2 Select G3FAX and click Connect F 19 84 3 Click Set host name F 19 85 ...
Page 1209: ...Chapter 20 Service Tools ...
Page 1210: ......
Page 1211: ...Contents Contents 20 1 Special Tools 20 1 20 2 Solvents and Oils 20 2 ...
Page 1212: ......
Page 1215: ...Dec 3 2004 ...
Page 1216: ......